16Operation of the Unit4 Operation of the Unit4.1 Operation Accessories4.1.1 With HSP5 cable and without operatorA special cable (part number 00.F5.0C0-0010) is necessary for the control of the KEBCOMBIVERT without operator. It is connected between the HSP5-interface X4A and aserial RS232-PC-interface (COM1 or COM2). The operation takes place via the PC-pro-gram COMBIVIS.The HSP5-cable has an integrated level converter. The connection of a serial standardcable would destroy the PC-interface.4.1.2 Digital operator (part number 00.F5.060-1000)As an accessory for the local operation of the KEB COMBIVERT F5 an operator is available.To prevent malfunctions, the inverter must be brought into nOP status before connecting/ disconnecting the operator (open control release). When starting the inverter, it is alwaysstarted with the last stored values or the factory setting.4.1.3 Interface operator (part number 00.F5.060-2000)The interface operator corresponds to the functional range of the digital operator. However,it is enhanced by a serial RS232/485-interface.A RS232-cable is needed to connect the interface operator with the PC. The assignmentis represented on the following page.ANTRIEBSTECHNIKSTARTSTOPFUNC.SPEEDENTERF/RANTRIEBSTECHNIK5 4 3 2 19 8 7 65-digit LED displayOperating / Error displayNormal "LED on"Error "LED blinks"Double function keyboardRS232/RS485(only 00.F5.060-2000)Interface controlBUS-Operation "LED on"(only 00.F5.060-2000)PIN RS485 Signal Meaning1 - - reserved2 - TxD Transmission signal/RS2323 - RxD Receive signal/RS2324 A’ RxD-A Receive signal A/RS4855 B’ RxD-B Receive signal B/RS4856 - VP Supply voltage-Plus +5V (Imax =10mA)7 C/C’ DGND Data reference potential8 A’ TxD-A Transmission signal A/RS4859 B’ TxD-B Transmission signal B/RS485