FORM NO. 56041603 - Klenzor ™ - 11ENGLISH / A-11SOLUTION SCREEN MAINTENANCEOnce a week (or more often if necessary), clean the Solution Screen (11). Drain the solution and recovery tanks. Lift the recovery tank from themachine and set it off to the side. Reach inside the solution tank and unthread the solution filter to remove.POWER CORD MAINTENANCEOnce a week (or more often if necessary), check the power cord for cracked or damaged insulation, exposed wires in the cord or plug, and damagedor missing ground pin. Repair or replace damaged cord or plug immediately.ADJUSTING THE BRUSH PRESSURESimply turn the Brush Pressure Adjustment Knob (17) clockwise to increase brush pressure and counter-clockwise to decrease the brush pressure.POWER BRUSH MAINTENANCECheck the brush daily. Remove any built-up string, hair or carpet fibers. When the machine is not in use it should be placed in the storage position.This will prevent the brush from taking a set which will increase the brush life and maintain the performance of the brush.REMOVING THE BRUSHCAUTION!Turn the power switch off (O) and unplug the machine, before changing the brushes.1 Empty both the recovery and solution tanks. Lift the recovery tank from the machine and set it off to the side.2 Place the Handle Assembly (19) into the upright storage position and tip the machine over onto its back.3 See Figure 7. Rotate the brush until the Drive Lug (D) is in a position where the fins on the drive lug are parallel to the floor.4 Grab the brush at the end with the Brush Retainer Clip (C) and pull straight out.5 Install a new brush at the drive lug end first then push the other brush end in until it snaps into the retainer clip.DCFIGURE 7revised 4/05