12 - FORM NO. 56041603 - Klenzor ™A-12 / ENGLISHTROUBLESHOOTINGIf the possible causes listed below are not the source of trouble, it is a symptom of something more serious. Contact your Kent Service Centerimmediately for service.TRIPPING THE CIRCUIT BREAKERThe Circuit Breaker (18) is located on the Control Panel; it protects the electrical circuit and brush motor from damage due to overload conditions. Ifthe circuit breaker is tripped try to determine the cause.Brush Circuit Breaker (5 Amp) Possible cause may be:1 Debris wrapped around the brush drive (remove debris)2 Brush setting too low (adjust to proper brush pressure setting)3 Electrical short circuit (have your Kent Service Center or qualified electrician check the machine)Once the problem has been corrected, push the button in to reset the circuit breaker. If the button does not stay in, wait 5 minutes and try again. If thecircuit breaker trips repeatedly, call your Kent Service Center for service.POOR WATER PICKUPPossible causes may be:1 Recovery Tank Full (empty recovery tank)2 Open recovery tank drain hose (secure drain hose cap or replace)3 Recovery hose not connected at vacuum shoe (connect hose to vacuum shoe)4 Recovery hose is kinked or damaged (replace the hose)5 Recovery tank cover gasket leak (replace gasket)6 Debris caught in vacuum shoe or recovery hose (clean vacuum shoe and recovery hose)INADEQUATE SOLUTION FLOWPossible causes may be:1 Solution tank empty (fill solution tank)2 Solution lines or screen clogged (flush lines and screen)TECHNICAL SPECIFICATIONS (as installed and tested on the unit)Model Klenzor™ 16 Klenzor™ 18Model No. 56265004 56265005Voltage/frequency V/Hz 120 / 50-60 120 / 50-60Rated Current Amp 13.3 14Protection Class (electrical)Sound Pressure Level (IEC 60704-1) dB (A)/20μPa 73.1 73.1Total Weight lbs/kg 99 / 45 NAVibrations at the Hand Controls (ISO 5349-1) m/s 2 0.72m/s 2 0.72m/s 2Solution Tank Capacity 7 gal (26.5l) 11 gal (41.5l)Recovery Tank Capacity 5 gal (19l) 8 gal (30l)