Version 2013-08-10Page 32 of 48Operating instructions 82132/3xxx CB 305 Overview of authorizationsThe authorizations of individual operators are as follows:Operator ID Codedesignation Authorization- Inspection key- Opening without OD/OST and without guard time- Assigning of a new master code- Resetting the lock- Changing the lock configurations using software withoutknowing the master code or changing it.00 Master code- Opening, if necessary, with silent alarm- Changing of the own code- Activating, blocking, releasing, deleting user and courier, withactivated double code as well- Activating / deactivating double code- Programming / deleting OD/OST- Neutralising the take-off contact- Reading out audit- Activating, deactivating silent alarm- Access via PC software01..30 User codes - Opening, if necessary, with silent alarm- Changing of the own code95 Courier code - Opening without OD/OST, if necessary, with silent alarm- Changing of the own code- Assembler code- Opening- Valid only until the real start-up of the lock,NOT A REAL CODE, not suitable for permanent useTable 2: Authorizations6 Overview of the programming commandsAction Command AuthorizationChanging own code P eachReading out audit P1MasterActivating + deactivating OD/OST P2Activating user P3Blocking + releasing user P4Deleting user P5Code status query P6Activating + deactivating double code P7Activating + deactivating silent alarm P8Acknowledging the take-off contact message P9Resetting the lock P0 KeyReassignment of the master code PTable 3: Programming commands