10E-730/630/750/79E/ R T Series Installation G uide - PK3677_T_04_16Activate the panic bar. The latch bolt or rodretracts fully.Turn the outside lever downward. The latch boltor rod does not retract.If the latch bolt or rod retracts, verify thatthe batteries are properly installed.If the lever feels tight (hard to turn, or doesnot return easily to its horizontal rest position),check the spindle length vs. the door thickness(the spindle may be too long). Check that theslotted end of the spindle is inserted in the lockhousing hub, not the exit device.A ProgrammingProgram the lock with at least one user, usingthe Oracode Maintenance Unit. Generate a validcode for this user. (Recommendation: generate acode that starts a day before today and finishesat least one day after installation/testing date, inorder to avoid check-in/check-out time periods)B Code entry and accessEnter the user code to validate complete lockoperation. Verify that the green LED flashes ateach key pressed and a longer green LED flashesat the end of the code entry. Turn the outsidelever. Make sure the latch bolt retracts fully.Release the lever, wait for the lock to return tothe locked mode (default settings is 5 secondsafter unlocking), and then turn the lever again.The latch bolt must not retract after thelock has returned to locked mode, whichis typically 5 seconds (max 15 sec ) afterunlocking, without first entering a valid usercodeCaution! Perform the following proceduresin order, with the door OPEN unless other-wise indicated.!1 Panic BarH TEST THE OPERATION OF THE 630 LOCK (For 730/750/79E lock go to Section E)2 Outside Lever3 Electronic