7Reset ProceduresThere are three different “Reset” levels available in the E-Plex 5000.Code 099# will reset the lock to the factory default settings exceptfor the access code length (Master, Manager Access User codesand Time / Date are retained if already programmed)Code 299# will delete all access and service user codes (Master,Manager and M-Unit * users are retained)Hard Reset will return the lock to factory mode including deleting allcodes, putting the lock back to factory default values (4 digit accesscode length) and making the master code 1-2-3-4-5-6-7-8. A hardreset is performed as follows.Insert key, turn and hold in open position.Within 5 seconds, press # and then release latchWhile red / green light flashes, press 1-2-3-4-5-6-7-8-# on keypadThe lock will reset. A green light with corresponding high pitch toneindicates reset is complete.Lock is now reset to the factory mode and the Master Code is now1-2-3-4-5-6-7-8.*M-Unit is only applicable when using optional E-Plex software.Procedure 1 - Program the Access Code LengthSetting the length of Access Codes must be the first lock programmablefunction you perform, because all your other access codes must havethe same length. If a user enters a code of a different length, the lockwill not accept it. Longer length Access Codes permit a greater numberof code possibilities, and thus higher security. The master code mustalways be 8 digitsRequired User Level: Master1. To configure the E-Plex 5000 programmable pushbutton lock,it must first be placed in Programming Mode.Important: This is the only programmable function thatcan be done during the factory mode using the factorymaster code. Except for changing from the factory code to anew master code.