Installation Manual Installation37k2evo702 - 201610Kaba c-lever and variants4.5.5 Variant with wireless option (E320)The supported functions depend on the system software used such as KEM. A de-tailed description of this option can be found in the Wireless planning guideline andin the respective instructions for the system software.Requirement:• Outside shield installed• Centring sleeve positioned in outside shield• Internal fitting with wireless module, door handle contact and additional circuitboard availableProcedure:1. Install internal fitting with wireless module accordingto the relevant version. See list below:c-lever standard variant [} 4.5.1]c-lever ES1 variant [} 4.5.2]c-lever short plate variant [} 4.5.3]c-lever rosette assembly variant [} 4.5.4]2. For doors that have a mortise lock with a microswitch.Connect mortise lock to micro switch and wirelessmodule.a) Remove wireless module (52) from the internal fit-ting.b) Remove connection terminal (53) from the pinheader of the wireless module at the same time.GNDGNDGNDCylindFrameBolt1 2 3 4 5 653521 2 3 4 5 67c) Connect the cable from the mortise lock with a microswitch to the individual terminals.1 GND Door frame contact2 Frame Door frame contact3 GND Mortise lock deadbolt contact4 Bolt Deadbolt contact5 GND Mortise lock cylinder contact6 Cylind. Cylinder contact7 Plug con-nection(Top left) handle – handle monitoring