ENadMinistratOr Menu (In Main menu 2/7, User Identification)Change PIN Code Administrator pin codechange.Factory PIN code: 0000Ask PIN PIN code inquiry selection:OFF / StartUp / MenuFactory Setting: OFF OFF: No PIN code inquiry.StartUp: Setup panel (P65) always asks forthe PIN code when the machine is turnedon. PF 65 is not affected and always workswithout PIN.Menu: Setup panel (P65) asks everytime for PIN code when MENU button ispressed and when the display is in channelinfo mode i.e. in start-up view. PIN codeinquiry is made only once when enteringthe menu. After that the menu button canbe pressed any time without PIN inquiry.ButtOn FunCtiOnsON / OFF Button Short Press: Panel returns to default start-up display view (Channel info display).Long Press: When setup panel (P65) is ON => Setup panel and all PF65 panels are turned OFF. Whensetup panel is OFF => Setup panel and all PF65 panels are turned ON.Pressed while machine is turning ON: Restore to factory shortcut. Panel will ask confirmation torestore factory setting.If Setup panel is OFF and some other PF65 panel is turned ON the Setup Panel turns also ON and willbe linked automatically to this PF panel (WF# function).F1 Button F1 button gives further information of selected memory channel.Pressed while machine is turned ON: Restore language selection to English.F2 Button F2 button can be used to select user.Selections: 1 – 10, Administrator.If Welding Process is MMA only Administrator is allowed.F3 Button (WF#) F3 button can be used to select Wire Feeder.Panel allows selecting only those WF numbers that are found connected on the sys-tem.Channel +/- Memory channel selection.Up/Down Button Moving Up/Down in menu.Right/Leftselection buttons(Soft Keys)Button function depends on where in menu you are.16FastMig Pulse 350, 450 / © Kemppi Oy / 1110