EN5. When wire feed stops, cut the wire at the contact tip and measure the length of the fedwire in mm.6. At the power source control panel, enter the length of the wire using the buttons below.To toggle betweenones, tens andhundredsTo add the number byoneTo subtract the numberby oneNOTE! If you enter a value that does not fit in, the machine forces the value within the acceptablelimits. This is to prevent you from entering false values.7. Press Wire Inch button again.• Wire feed starts and continues for 2 seconds.8. When wire feed stops, cut the wire and measure its length.9. At the power source control panel, enter the length of the wire in the same manner as instep 610. Press Wire Inch button.To skip the calibration• If you want to skip the calibration, press Crater Fill button for 3 seconds. The machineexits the calibration mode.• If the device is left idle for 5 minutes, it automatically exits the calibration mode.• If the device is turned off before the step 10, it automatically exits the calibration mode,and the old calibration values remain.19© Kemppi Oy / 1445