EN4.3 wEldIng pArAmEtrEs And FunCtIons4.3.1 welding parametres (in edit Channel menu 2/6)mIgWFSpeed 0.7 – 25 m/min 0.05 m/min steps when WFSpeed < 5 m/min and0.1 m/min steps when WFSpeed > 5 m/minWFS-Max Set the limit for maximum WFSpeedWFS-Min Set the limit for minimum WFSpeedVoltage 8 – 50V 0.1V steps Controls the length of the arcDynamics -9 – 9 Factory setting is 0 Controls the short circuit behaviour of the arc. The lowerthe value the softer the arc is. The higher the value therougher the arc is.1-mIgWFSpeed 0.7 – 25 m/min 0.05 m/min steps when WFSpeed < 5 m/min and0.1 m/min steps when WFSpeed > 5 m/minWFS-Max Set the limit for maximum WFSpeedWFS-Min Set the limit for minimum WFSpeedFineTuning Factory setting is 0( = curve point)Adjusts the arc voltage of the curve within certainlimits. In other words, it adjusts the length of the arcwithin certain limitsFineTuningMax 0 – 9 0.5 steps Set the limit for maximum arc lengthFineTuningMin -9 – 0 0.5 steps Set the limit for minimum arc lengthDynamics -9 – 9 Factory setting is 0 Controls the short circuit behaviour of the arc. The lowerthe value the softer the arc is. The higher the value therougher the arc is.pulsE mIgWFSpeed 0.7 – 25 m/min 0.05 m/min steps when WFSpeed < 5 m/min and0.1 m/min steps when WFSpeed > 5 m/minWFS-Max Set the limit for maximum WFSpeedWFS-Min Set the limit for minimum WFSpeedFineTuning Factory setting is 0( = curve point)Adjusts the base current of the curve in certain limits.In other words, it adjusts the length of the arc in certainlimits.FineTuningMax 0 – 9 0.5 steps Set the limit for maximum arc lengthFineTuningMin -9 – 0 0.5 steps Set the limit for minimum arc lengthDynamics -9 – 9 Factory setting is 0 Controls the short circuit behaviour of the arc. The lowerthe value the softer the arc is. The higher the value therougher the arc is.Pulse Current -10% – 15% Factory Settingis 0%Reduces the pulse current of the curve at the maximum10% and raises it at the maximum 15%.12Kemparc pulse 350, 450 / © Kemppi Oy / 1044