1-44 (No.RA077)7. OpenSquelch (5)(DMR)1) Adj item:[Open Squelch (5) (DMR)]2) Adj point: 5 points[Low], [Low'], [Center], [High'], [High]3) SSG output: -123.5dBm (0.15uV) / NomodulationSSG-ANTDistortion meterOscilloscope-SP outputFPU Input signal from SSG, press [Start] buttonto adjust, and after that press [OK] button tostore the adjustment value.8. Low RSSI*51) Adj item:[Low RSSI (Analog Narrow)]2) Adj point: 5 points[Low], [Low'], [Center], [High'], [High]3) SSG output: -120dBm (0.22uV)MOD:1kHz/±1.5kHzSSG-ANTDistortion meterOscilloscope-SP outputFPU Input signal from SSG, press [Start] buttonto adjust, and after that press [OK] button tostore the adjustment value.*5: Because Low RSSI at -118dBm (Analog Wide, NXDN Narrow, NXDN Very Narrow and DMR) is adjusted by adjusting Low RSSIat -120dBm (Analog Narrow), it is not necessary to adjust Low RSSI at -120dBm (Analog Wide, NXDN Narrow, NXDN Very Narrowand DMR).9. High RSSI*61) Adj item:[High RSSI (Analog Narrow)]2) Adj point: 5 points[Low], [Low'], [Center], [High'], [High]3) SSG output:-80dBm (22.4uV)MOD:1kHz/±1.5kHzSSG-ANTDistortion meterOscilloscope-SP outputFPU Input signal from SSG, press [Start] buttonto adjust, and after that press [OK] button tostore the adjustment value.*6: Because High RSSI at -80dBm (Analog Wide, NXDN Narrow, NXDN Very Narrow and DMR) is adjusted by adjusting High RSSIat -80dBm (Analog Narrow), it is not necessary to adjust High RSSI at -80dBm (Analog Wide, NXDN Narrow, NXDN Very Narrowand DMR).10. Squelch(Tight)1) Adj item:[Tight Squelch (Analog Wide)]2) Adj point: 5 points[Low], [Low'], [Center], [High'], [High]3) SSG output: -116dBm (0.35uV)MOD:1kHz/±1.5kHzSSG-ANTDistortion meterOscilloscope-SP outputFPU Input signal from SSG, press [Start] buttonto adjust, and after that press [OK] button tostore the adjustment value.1) Adj item:[Tight Squelch (Analog Narrow)]2) Adj point: 5 points[Low], [Low'], [Center], [High'], [High]3) SSG output: -116dBm (0.35uV)MOD:1kHz/±1.5kHzSSG-ANTDistortion meterOscilloscope-SP outputFPU Input signal from SSG, press [Start] buttonto adjust, and after that press [OK] button tostore the adjustment value.NX-1300 Series (K4) typeItem Condition Measurement Adjustment Specifications/RemarksPC tuning mode Point Method