NX-90044ADJUSTMENTControlsKMC-36ModularMIC jackKeypad[HOOK]Channel Up/Down key[PTT]Power switchVolume Up/Down keyProgrammable function keysPanel Test Mode■ Test mode operation featuresThis transceiver has a test mode. To enter test mode,press and hold the [ ] key while turning the transceiverpower ON. Before the transceiver enters test mode, thefrequency version information appears on the LCD mo-mentarily. Test mode can be inhibited by programming. Toexit test mode, turn the transceiver power OFF. The follow-ing functions are available in test mode.■ Key operationKey “FNC” not appears on the sub LCD displayFunction Display[ ] / [ ] Test CH up/down Channel No.[ ] / [ ] Volume up/down -[ ] Push: Squelch level upHold: Squelch offSquelch levelSquelch off: icon appears[ ] Wide 5k/Wide 4k/Narrow/Very narrowWide 5k: “w”Wide 4k: “s”Narrow: “n”Very narrow: “v”[ ] Shift to panel tuning mode -[ ] Function on “FNC” appears on the subLCD display[ ] MSK 1200bps and 2400bps 2400bps: icon appears[ ] Test signaling CH up Signaling No.Key “FNC” not appears on the sub LCD displayFunction DisplayMicrophone key[PTT] Transmit -[0] to [9]and [A]to [D],[#], [ ]Use as the DTMF keypad.If a key is pressed duringtransmission, the DTMFcorresponding to the keythat was presses is sent.-Key “FNC” appears on the sub LCD displayFunction Display[ ] Talk Around on/off On: icon appears[ ] Analog/NXDN Analog: “A”NXDN: “N”[ ] / [ ] Function off -[ ] - -[ ] LCD all lights LCD all point appears[ ] High power/Low power Low: icon appears[ ] Function off -[ ] Compander on/off On: icon appears[ ] Beat shift on/off On: icon appearsMicrophone key[PTT] Transmit[0] to [9]and [A]to [D],[#], [ ]Function off -• LED indicatorRed LED Lights during transmission.Green LED Lights when there is carrier.• Sub LCD indicator“FNC” Appears at function on.• LCD display in panel test modeChannel No.(Power ON)(After 2sec.)Market code Frequency range“800MHz”:806~870MHzAw: Analog wide 5k modeAs: Analog wide 4k modeAn: Analog narrow modeNn: NXDN narrow modeNv: NXDN very narrow modeSub LCD displaySignaling No.Main LCD displaySquelch level(Analog mode only)TemperatureKAw SQ 5 1 - 12 5+8 0 0 HM zTalk Around