NXR-70089ADJUSTMENTItem ConditionMeasurement AdjustmentSpecifications / RemarksTest-equipment Unit Terminal Unit Parts Method27. DTMFDeviation1) Channel: 3 (Center)Wide/Narrow: Analog Wide 5kConnect the deviation meterto the TX ANT end via the ATT.Deviation meter settingHPF: OFF, LPF: 15kHzDe-emp: OFFDetector: (p-p)/2DeviationmeterRear TX ANT PCADJ±2.85kHz ±0.05kHzConnect the deviation me-ter to the TX ANT end viathe ATT.2) Channel: 3 (Center)Wide/Narrow: Analog Wide 4k±2.4kHz ±0.05kHz3) Channel: 3 (Center)Wide/Narrow: Analog Narrow±1.50kHz ±0.05kHz28. CourtesyToneDeviation1) Channel: 3 (Center)Wide/Narrow: Analog Wide 5kConnect the deviation meterto the TX ANT end via the ATT.Deviation meter settingHPF: OFF, LPF: 15kHzDe-emp: OFFDetector: (p-p)/2DeviationmeterRear TX ANT PCADJ±1.00kHz ±0.05kHzConnect the deviation me-ter to the TX ANT end viathe ATT.2) Channel: 3 (Center)Wide/Narrow: Analog Wide 4k±0.8kHz ±0.05kHz3) Channel: 3 (Center)Wide/Narrow: Analog Narrow±0.50kHz ±0.05kHz29. TDDeviation1) Channel: 3 (Center)Wide/Narrow: Analog Wide 5kConnect the deviation meterto the TX ANT end via the ATT.Deviation meter settingHPF: OFF, LPF: 3kHzDe-emp: OFFDetector: +peak, –peakAG setting: 0.1kHz/0.5Vp-p (177mVrms)DeviationmeterAGDVMRear TX ANTCONTROLI/O jack TD(pin 8)PCADJ±0.75kHz ±0.02kHzConnect the deviation me-ter to the TX ANT end viathe ATT.2) Channel: 3 (Center)Wide/Narrow: Analog Wide 4k±0.75kHz ±0.02kHz3) Channel: 3 (Center)Wide/Narrow: Analog Narrow±0.75kHz ±0.02kHz30. TransmitAudio Input(TA)1) Channel: 3 (Center)Wide/Narrow: Analog Wide 5kConnect the deviation meterto the TX ANT end via the ATT.Deviation meter settingHPF: OFF, LPF: 15kHzDe-emp: OFFDetector: +peak, –peakAG setting: 1kHz/280mVrmsDeviationmeterAGDVMRear TX ANTCONTROLI/O jack TA(pin 9)PCADJ±3.00kHz ±0.03kHzConnect the deviation me-ter to the TX ANT end viathe ATT.