NXR-800801-2. Hardware Traceability (Method 1)� Procedure for IC703 (Main MPU) traceabilityPower Source VoltageTest Point Normal Output VoltageIC329 (pin 4) 3.3VDCIC306 (pin 3) 1.5VDCCorrect conditionConfirmation of Clock frequencyTest Point Proper FrequencyR725 25.8048MHz(either end of R725 is OK)Correct conditionConfirmation of Reset controlTest Point Normal VoltageIC726 (pin 4) 3.3VDCCorrect conditionParts other than IC703 are malfunctioning.� Traceability Procedure of IC324 (TX Vocoder_DSP)Confirmation of Power Source VoltageTest Point Normal Output VoltageIC307 (pin 1) 1.5VDCIC15 (pin 3) 3.3VDCCorrect conditionConfirmation of Clock frequencyTest Point Proper FrequencyR679 12.288MHz(either end of R679 is OK)Correct conditionConfirmation of Reset controlTest Point Normal Output VoltageR521 3.3VDC(either end of R521 is OK)Correct conditionParts other than IC324 are malfunctioning.Confirmation of IC329 (pin 5) outputRemove R711 and R721.If the voltage is 3.3VDC, IC703 is malfunctioning.Confirmation of IC306 (pin 3) outputRemove R715 and R716.If the voltage is 1.5VDC, IC703 is malfunctioning.If 25.8048MHz oscillation cannot be confirmed:X700 is malfunctioning or a component aroundX700 is malfunctioning.Clock oscillation amplitude is weak:The drive circuit for IC703 is malfunctioning.Check the voltage of pin 1 and pin 2 of IC726:Pin 1 = 3.3VDC. If not, IC325 is malfunctioning.Pin 2 = 3.3VDC. If not, IC708 is malfunctioning.Confirmation of IC307 (pin 1) outputRemove R486 and if 1.5VDC, IC324 is malfunction-ing.Confirmation of IC15 (pin 3)Remove R488 and if 3.3VDC, IC324 is malfunction-ing.If 12.288 MHz oscillation cannot be confirmed:X300 is malfunctioning or a component aroundX300 is malfunctioning.The clock oscillation amplitude is weak.The drive circuit for IC324 is malfunctioning.Remove R521 and then measure the voltage ofIC325 side:If not 3.3VDC, IC325 is malfunctioning.Remove R521 and confi rm the voltage of pad sideof IC325:If the voltage is 3.3VDC, IC324 is malfunctioning.AbnormalconditionAbnormalconditionAbnormalconditionAbnormalconditionAbnormalconditionAbnormalconditionTROUBLE SHOOTING