TK-218034Item ConditionMeasurement AdjustmentSpecifications/RemarksTest-equipment Unit Terminal PartsUnit MethodADJUSTMENT11. VOX1 1) Adj item : [VOX1] AG Panel Universal Panel After apply signaladjust Adjust : [✳✳✳] connector from AG, press [B]AG : 1kHz/45mV at MIC terminal key that numericwill be stored in12. VOX10 1) Adj item : [VOX10] memory.adjust Adjust : [✳✳✳]AG : 1kHz/3mV at MIC terminal13. QT deviation 1) Remove the panel tuning Power meter Panel ANT Panel Selector 0.35kHz ± 50Hzadjust cable assembly from the knobuniversal connector. Deviation UniversalAdj item : [n QT] meter connectorAdjust : [✳✳✳] OscilloscopeDeviation meter filter AGLPF : 3kHz AF VTVMHPF : OFF• Narrow 2) Adj item : [nL QT] →[nC QT] → [nH QT]Adjust : [✳✳✳]PTT : ON• Wide 4k 3) Adj item : [s QT] 0.60kHz ± 50HzAdjust : [✳✳✳]PTT : ON• Wide 5k 4) Adj item : [w QT] 0.75kHz ± 50HzAdjust : [✳✳✳]PTT : ON14. DQT 1) Adj item : [n DQT] 0.35kHz ± 50Hzdeviation Adjust : [✳✳✳]adjust Deviation meter filterLPF : 3kHzHPF : OFF• Narrow 2) Adj item : [nL DQT] →[nC DQT] → [nH DQT]Adjust : [✳✳✳]PTT : ON• Wide 4k 3) Adj item : [s DQT] 0.60kHz ± 50HzAdjust : [✳✳✳]PTT : ON• Wide 5k 4) Adj item : [w DQT] 0.75kHz ± 50HzAdjust : [✳✳✳]PTT : ON15. LTR 1) Adj item : [n LTR] 0.75kHz ± 0.10kHzdeviation Adjust : [✳✳✳]adjust Deviation meter filterLPF : 3kHzHPF : OFF• Narrow 2) Adj item : [nL LTR] →[nC LTR] → [nH LTR]Adjust : [✳✳✳]PTT : ON• Wide 3) Adj item : [w LTR] 1.00kHz ± 0.10kHzAdjust : [✳✳✳]PTT : ON