TK-300018ADJUSTMENTTest Equipment Required for AlignmentTest Equipment Major Specifications1. Standard Signal Generator (SSG)Frequency Range 400 to 480MHzModulation Frequency modulation and external modulationOutput –127dBm/0.1μV to greater than –47dBm/1mV2. RF Power MeterInput Impedance 50ΩOperation Frequency 400 to 480MHzMeasurement Range Vicinity of 10W3. Deviation Meter Frequency Range 400 to 480MHz4. Digital Volt Meter (DVM) Measuring Range 10mV to 10V DCInput Impedance High input impedance for minimum circuit loading5. Oscilloscope DC through 30MHz6. High SensitivityFrequency CounterFrequency Range 10Hz to 1000MHzFrequency Stability 0.2ppm or less7. DC Ammeter 5A8. AF Volt Meter (AF VTVM) Frequency Range 50Hz to 10kHzVoltage Range 1mV to 10V9. Audio Generator (AG) Frequency Range 50Hz to 5kHz or moreOutput 0 to 1V10. Distortion Meter Capability 3% or less at 1kHzInput Level 50mV to 10Vrms11. Spectrum Analyzer Measuring Range DC to 1GHz or more12. Tracking Generator Center frequency 50kHz to 600MHzOutput Voltage 100mV or more13. 8Ω Dummy Load Approx. 8Ω, 3W14. Regulated Power Supply 5V to 10V, approx. 3AUseful if ammeter equipped■ Antenna connector adapterThe antenna connector of this transceiver uses an SMAterminal.Use an antenna connector adapter [SMA(f) – BNC(f) orSMA(f) – N(f)] for adjustment. (The adapter is not providedas an option, so buy a commercially-available one.)BATT+ (7.5V)BATT– (GND)– +■ DC SupplyBATT+, BATT– : External power supply terminal (Fastenit with an alligator clip.)