TK-52105REALIGNMENT7. Clone Mode (K2 and K3 models only)Programming data can be transferred from one trans-ceiver to another by connecting them via their external uni-versal connectors. The operation is as follows (the transmittransceiver is the master and the receive transceiver is aslave).The following data cannot be cloned.• Tuning data• Embedded message with password• Model name data• ESN dataKey guide on the "INPUT PASSWORD" display.• CNF([A] key): The password confirmation• DEL([B] key): Delete the least digit from the current pass-word number• SET([D] key): Determine the least digit of the passwordnumber1. Press and hold the [Side2] and [PTT] keys while turningthe transceiver power on and then release the [Side2] keyfirst. If the Read authorization password is set to the trans-ceiver, the transceiver displays “CLONE LOCK”. If thepassword is not set, the transceiver displays “CLONEMODE”.2. When you enter the correct password, and “CLONEMODE” is displayed, the transceiver can be used as thecloning master. The following describes how to enter thepassword.3.• How to enter the password using the keypad (K3 modelonly);If the [D] key is pressed while "CLONE LOCK" is displayed,the Read authorization password input screen (INPUTPASSWORD) is displayd.If one of keys 0 to 9 is pressed while "INPUT PASSWORD"is displayed, the pressed number is displayed on the LCD.Each press of the key shifts the display in order to the left.When you enter the password and press the [A] or [✳]key, “CLONE MODE” is displayed if the entered pass-word is correct. If the password is incorrect, “CLONELOCK” is redisplayed.• How to enter the password using the [Side2] and [Side3]keys (K2 and K3 models);If the [D] key is pressed while "CLONE LOCK" is displayed,the Read authorization password input screen (INPUTPASSWORD) is displayd.If the [Side2] key or [Side3] key is pressed while "INPUTPASSWORD" is displayed, the number (0 to 9) flashes onthe LCD. When you press the [D] key, the currentlyselected number is determined. If you press the [A] keyafter entering the password in this procedure, “CLONEMODE” is displayed if the entered password is correct. Ifthe password is incorrect, “CLONE LOCK” is redisplayed.4. Power on the slave transceiver.5. Connect the cloning cable (part No. E30-3325-05) to theuniversal connectors on the master and slave.6. Press the [Side1] or [A] key on the master while the mas-ter displays “CLONE MODE”. The data of the master issent to the slave. While the slave is receiving the data,“PROGRAM” is displayed. When cloning of data is com-pleted, the master displays “END”, and the slave auto-matically operates in the User mode. The slave can thenbe operated by the same program as the master.7. The other slave can be continuously cloned. When the[Side1] or [A] key on the master is pressed while the mas-ter displays “END”, the master displays “CLONEMODE”. Carry out the operation in step 4 to 6.Notes:• Can not be cloned if the password (over write password)is programmed to the slave.• "Model Name and Market Code" must be same to clonethe transceiver. However, it may be unable to clone thetransceiver depending on the enhanced features settings.(Refer to the FPU for the enhanced features details.)8. Self Programming Mode(K2 and K3 models only)Write mode for frequency data and signaling etc. To beused ONLY by the authorized service person maintaining theuser's equipment. After programming, reset the FPU to the"Self- Programming" disabled mode. Transceivers CANNOTbe delivered to the end-user in the self-programming mode.The following setup items in the channels programmed bythe FPU can be changed using the self-programming mode.The addition of new channel and the deletion of channel thathas already been programmed by the FPU cannot beperformed using the self-programming mode.• RX frequency• TX frequency• Channel type• TX mode (When the channel type is selected "MIXED".)• Channel spacing• RX signaling• TX signaling• RX NAC• TX NAC• Talkgroup list numberNote:The personality will be also changed when the above-mentioned items is changed. (Refer to the FPU for thepersonality details.)Key guide on the "INPUT PASSWORD" display.• CNF([A] key): The password confirmation• DEL([B] key): Delete the least digit from the current pass-word numberCloning cable(E30-3325-05)Fig. 2