33ADJUSTMENTMeasurementTest-equipment Unit TerminalAdjustmentUnit Parts Method Specifications/RemarksConditionItemTK-54007. MIC 1) Set panel tuning mode. Deviation Panel ANT Panel Top 1/ Fixed digit numbersensitivity CH : 4 (Center) meter Top 2 129.adjustment LCD display : MIC LO OscilloscopePTT : ONSet at constant value 129. AG Side UniversalPress [Side 2] to store the AF VTVMdigit number after adjustment.8. VCO/VCXO 1) Set panel tuning mode. Make the demodula- Remember to setbalance CH : 4 (Center) tion waveform into oscilloscope’s coupling to DC.adjustment LCD display : BAL LO square shape.Deviation meter filter settingLPF : 3kHzHPF : OFFDe-emphasis : OFFPTT : ONPress [Side 2] to store thedigit number after adjustment.9. VCO/VCXO 1) Set panel tuning mode.balance CH : 4 (Center)adjustment LCD display : BAL t LO(TA) PTT : ONPress [Side 2] to store thedigit number after adjustment.10. APCO high 1) Set panel tuning mode. Deviation Panel ANT 2827Hz 2771~2883Hzdeviation CH : 4 (Center) meteradjustment LCD display : HDVA LODeviation meter filter settingLPF : 3kHzHPF : OFFDe-emphasis : OFFDET : Peak (+/–)PTT : ONPress [Side 2] to store thedigit number after adjustment.11. APCO high 1) Set panel tuning mode,deviation then press [Orange] key toadjustment enter the 3 point adjustmentat low mode.frequency LCD display : HDVA L LOPTT : ONPress [Side 2] to store thedigit number after adjustment.12. APCO high 1) Set panel tuning mode.deviation and press [Side 2] key to setadjustment high frequency.at high LCD display : HDVA H LOfrequency PTT : ONPress [Side 2] to store thedigit number after adjustment.