6814 SCAN6 Repeat step 5 to specify the center slow downfrequency points. You can specify a maximum of5 frequency points for each channel.7 If you want to clear the slow down frequencypoints that you previously stored, press and holdQUICK MEMO [M.IN] for 1 second. Aconfirmation beep sounds and the transceiverclears all the slow down frequency points youspecified in the memory channel.Note: You must clear all the previous slow down frequencypoints; you cannot clear only specific points.8 Press [VFO/M] to return to VFO mode.9 Press [SCAN/ SG.SEL] to start the Program Scanwith the slow down frequency point(s).Note:uDuring the Program Scan, you can turn the RIT/ SUB control toadjust the scanning speed. Turn the control clockwise/ counter-clockwise to slow down/ speed up the scan. The Program Scanspeed indicator appears on the main dot-matrix display duringthe Program Scan; P1 is the fastest speed and P9 is the slowest.uYou cannot change the Program Scan speed in FM mode.uYou cannot change the scan speed on the sub-receiver.uYou cannot specify the Program Scan slow down frequency pointfor FM mode.SCANHOLDThis function stops Program Scan for approximately5 seconds, then resumes Scan when you jump to thedesired frequency by turning the Tuning control or theMULTI/ CH control, or by pressing Mic [UP]/ [DWN].To use this function, access Menu No. 09, and selectON. The default is OFF.MHzSCANWhen you operate the main transceiver or sub-receiver in VFO mode, you can scan an entire 1 MHzfrequency range within the current VFO frequency.1 Press [VFO/M] to select VFO mode.2 Select the desired frequency to perform the MHzScan. If you want to scan the entire 145 MHzfrequency, for example, select 145.650 MHz.Scan will operate between 145.00000 MHz and145.99999 MHz.3 Press and hold [1MHz/ SEL] to start the MHz Scan.4 Turn the RIT/ SUB control to adjust the scanspeed.5 To stop the MHz Scan, press [SCAN/ SG.SEL] or[CLR].Note:uYou cannot change the MHz Scan speed in FM mode.uYou cannot change the scan speed on the sub-receiver.MEMORY SCANMemory Scan monitors all memory channels in whichyou have stored frequencies (All-channel Scan) or onlya desired group of memory channels (Group Scan).Scan automatically stops at a channel where a signalis present, regardless of the operating mode. Thetransceiver will either remain on that channel for ashort time (Time-operated mode) or until the signaldrops out (Carrier-operated mode). Use Menu No. 10to select either mode. The default is Time-operated.SCANRESUMEMETHODThe transceiver stops scanning at the frequency (ormemory channel) where a signal is detected. It thencontinues scanning according to which resume modeyou have selected. You can choose one of thefollowing modes. The default is Time-operated mode.• Time-Operated modeThe transceiver remains on a busy frequency (ormemory channel) for approximately 6 seconds,then continues to scan, even if the signal is stillpresent.• Carrier-Operated modeThe transceiver remains on the busy frequency (ormemory channel) until the signal drops out. Thereis a 2 second delay between signal dropout andscan resumption.1 Press [MENU] to enter Menu mode.2 Turn the MULTI/ CH control to select Menu No. 10.3 Press [+]/ [–] to select TO (Time-Operated) or CO(Carrier-Operated).4 Press [MENU] to complete the setting and exitMenu mode.You can lock out the memory channels that youprefer not to monitor while scanning. To do this, referto “Memory Channel Lockout” {page 62}.ALL-CHANNELSCANUse the following procedure to scan all the memorychannels that contain frequency data in sequence,ignoring the Memory Group number.1 Select Time-operated or Carrier-operated modevia Menu No. 10.2 Press [VFO/M] to enter Memory Recall mode.3 Turn the MAIN SQL or SUB SQL control to adjustthe squelch threshold.4 Press [FUNC], [SCAN/ SG.SEL] to enter ScanGroup Select mode.• The selected Groups appear in a larger font.5 Press [•/ DCS/SEL] to deselect all Groups so thatthe transceiver scans the memory channelsequentially, ignoring the Memory Group numberdata.