Contents - Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Measurement Resources
- B1505A Mainframe Furnished Accessories
- B1505A Modules and Mainframe Options
- Module type and locations
- N1259A Test Fixture for Power Device
- N1265A Ultra High Current Expander/Fixture
- N1266A High Voltage Source Monitor Unit Current Expander
- N1266A Compatibility with Fixture and Module Selector
- Fast Switch
- N1268A Ultra High Voltage Expander
- N1271A Thermal Test Enclosure and Related Accessories
- Measurement Capability on Thermal Test
- Accessories for Wafer Prober and Your Own Test Fixture
- Other Accessories
- Retrofit Products for B1505A
- Conversion Kit from B1500A to B1505A
- Upgrade Kit for N1259AU Test Fixture
- Upgrade Kit for N1265AU Test Fixture
- Note for 4142B Users
- Input Connection
- To Connect Interlock Circuit
- Output Connection
- To Connect DUT
- To Use Options
- N1259A-010 Inline Package Socket module
- N1259A-011 Universal Socket Module
- N1259A-012 Blank PTFE Board
- N1259A-013 Curve Tracer Test Adapter Socket Module
- N1259A-014 Gate Charge Socket Module
- Inline Package Socket module (N1265A-010)
- Universal Socket Module (N1265A-011)
- Curve Tracer Test Adapter Socket Module (N1265A-013)
- Gate Charge Socket Module (N1265A-014)
- Blank Silicon Plate (N1265A-002)
- Universal R-Box (N1265A-035)
- Protection Adapter (N1265A-040)
- pin Inline Package Socket Module
- N1273A-011 Universal Socket Module
- N1273A-013 Curve Tracer Test Adapter Socket Module
- Accessories for Connecting a DUT
- Connection Overview
- To Connect High Voltage R-Box
- To Use Universal R-Box
- To Connect HCSMU Adapter
- To Connect Dual HCSMU Adapter
- To Connect 16493S-021
- To Connect Protection Adapter
- To Connect High Voltage Bias Tee
- To Connect Module Selector
- To Connect HVSMU/HCSMU Fast Switch
- To Connect HVSMU Current Expander
- To Connect Ultra High Current Expander
- Connecting System Cable to N1265A
- To Connect Ultra High Voltage Expander
- To Connect Device Capacitance Selector
- To Connect Gate Charge Adapter
- To Connect N1274A
- To Connect N1275A
- To Install an Interlock Circuit
- Procedure
- About Cable Connections
- To Make Connection to Reduce Leakage Current
- To Make Connection to Measure Low Resistance
- To Connect UHVU/HVSMU/HVMCU Output
- Package Device Measurement Configuration Examples
- kV, 20A Configuration (B1505AP-H20 equivalent)
- kV, 500 A or 1500 A Configuration (B1505AP-H50 or B1505AP-H70 equivalent)
- Capability to 3 kV, 20 A Configuration
- kV, 20A, High Voltage Medium Current Configuration
- kV, 40 A Configuration
- or HPSMU) to 3 kV, 500A Configuration
- kV, 500 A, High Voltage Medium Current Configuration
- Configuration Examples for Lateral Device Measurement with Wafer Prober
- kV, 20 A Measurement for On-Wafer Lateral Device
- kV, 20 A, Capacitance Measurement for On-Wafer Lateral Device
- Capability to 3 kV, 20 A, Capacitance Measurement for On-Wafer Lateral Device
- kV, 40 A Measurement for On-Wafer Lateral Device
- kV, 500 A Measurement for On-Wafer Lateral Device
- kV, 500 A, Capacitance Measurement for On-Wafer Lateral Device
- Lateral Device
- Configuration Examples for Vertical Device Measurement with Wafer Prober
- kV, 20 A Measurement for On-Wafer Vertical Device
- kV, 20 A, Capacitance Measurement for On-Wafer Vertical Device
- Capability to 3 kV, 20 A, Capacitance Measurement for On-Wafer Vertical Device
- kV, 40 A Measurement for On-Wafer Vertical Device
- kV, 500 A Measurement for On-Wafer Vertical Device
- kV, 500 A, Capacitance Measurement for On-Wafer Vertical Device
- Vertical Device
- using the N1267A
- Kelvin Connection with the N1259A Test Fixture for Package Device
- Non-Kelvin Connection with Prober for On-Wafer Lateral Device
- Kelvin Connection with Prober for On-Wafer Lateral Device
- Upgrading from existing B1505A
- Example of how to upgrade existing B1505A
|
Keysight B1505A Configuration and Connection Guide 1-61Configuration GuideRetrofit Products for B1505ARetrofit Products for B1505AThe Keysight B1505A has 10 slots so that users can install appropriate modules intoB1505A mainframe. The retrofit module product is available to add more modules intoexisting B1505A mainframe. These modules have to be installed in Keysight Technologiesservice center to meet the specifications.The following table lists the module products and the available accessories.Table 1-28 Module products and available accessoriesModel/Option Description NoteB1505AU Upgrade kit for B1505ASoftware license to use advanced functionsB1505AU-SWS EasyEXPERT Extension support and subscription • B1505A users who have notpurchased a B1505A-SWShave to update EasyEXPERTsoftware to version 5.5 orlater.• The B1505AU-SWS includes15 licenses which can beused for both EasyEXPERTand Desktop EasyEXPERT.Measurement moduleB1505AU-010 High Power Source/Monitor Unit Module (B1510A) Modules are NOT furnished withany cables. Order the requiredcables and accessories separately.B1505AU-011 Medium Power Source/Monitor Unit Module(B1511B)B1505AU-012 High Current Source Monitor Unit Module (B1512A)B1505AU-013 High Voltage Source Monitor Unit (B1513C)B1505AU-014 Medium Current Source Monitor Unit (B1514A)B1505AU-020 Multi Frequency Capacitance Measurement UnitModule (B1520A)B1510A HPSMU, B1511A/B MPSMU and B1514A MCSMU cables16494A-001 1.5m length triaxial cable16494A-002 3 m length triaxial cable16494A-003 80 cm length triaxial cable16494A-004 40 cm length triaxial cable16494A-005 4 m length triaxial cable
PreviousNext |