4EN6. MaintenanceTo ensure that the level of safety of the installation is maintained and that the system remains reliable and operational, it must be serviced regularlyin observance of the safety regulations given in this manual and established legislation.The gearmotor must be serviced no later than 6 months after commissioning.01. Disconnect all power supplies02. Check for any deterioration in automation system components, paying special attention to erosion or oxidation of its structural parts.Replace any parts which are below the required standard.03. Check that all screw fasteners are fully tightened down04. Check the wear of all moving parts and replace any worn components05. Connect the power supplies up again, and run all the tests and checks described in Chapter 5.For the other equipment in the system, refer to its user manuals.7. Dispotal of the productThis product is an integral part of the automation and must be scrapped with it.At the end of the product’s service life, the product must be scrapped by qualified staff.This product is made up of a variety of materials, some of which can be recycled while others must be disposed of. Check that regulatoryrecycling and scrapping facilities are available locally.Caution! – some parts of the product may contain polluting or hazardous substances which, if disposed of into the environment, constituteserious environmental and health risks.As indicated by the symbol, the product may not be disposed of as domestic waste.Sort the materials for disposal, according to the methods envisaged by current legislation in your area, or return the product tothe retailer when purchasing a new version.Caution! – Local legislation may envisage serious fines in the event of abusive disposal of this product.8. Technical specificationsWARNINGS: • All technical specifications stated in this section refer to an ambient temperature of 20°C (± 5°C). • King Gates reserves theright to apply modifications to products at any time when deemed necessary, while maintaining the same intended use and functionality.MODEL LINEAR500230 LINEAR50024 LINEAR400230 LINEAR40024Motor voltage [V] 230 24 230 24Frequency [Hz] 50 DC 50 DCMax gate length [m] 4.5 4.5 3 3Max gate weight (kg) 250 250 300 300IP protection rating 54 54 54 54Operating temperature [C°] -20 to +50 -20 to +50 -20 to +50 -20 to +50Weight of motor [kg] 6 5.5 6 5.5Speed [m/s] 0.016 0.014 0.016 0.014Travel [mm] 500 500 400 400Capacitor [mF] 7 - 7 -Nominal current draw [A] 1.1 1.1 1.1 1.1Maximum current draw [A] 1.5 5 1.5 5Nominal power draw [W] 250 30 250 30Maximum power draw [W] 340 120 340 120Nominal force [N] 300 300 300 300Maximum force [N] 2000 1800 2000 1800Cycles (cycles/hour) 24 continuous 24 continuousDimensions [mm] 800 x 100 x 177 h 800 x 100 x 177 h 800 x 100 x 177 h 800 x 100 x 177 h