34EOLO - COMFORT 80ENALARM CAUSE SOLUTION INTERVENTIONAL 8 - FAILUREDEPRESSObstructed exhaustThe exhaust chimney is partially or tatally obstructed.Please contact a Specialized Stove-repairer who checksthe stove exhaust up to the chimney pot. Please have itimmediately cleaned. It can be harmful to health to runthe stove with the obstructed chimney.Faulty exhaust fanThe pellets can burn also thank to chimney flue depressionwithout the aid of the exhaust fan. Have the exhaust fanimmediately replaced. It can be harmful to health to runthe stove without exhaust fan.Obstructed outletconnector Clean the outlet connector.Faulty pressostat Clean the pressostat.Faulty mother board Replace the mother board.Extreme chimney lenghtContact a Specialized Stove-repairer and check that theexhaust chimney is in accordance with the regulations:see CHIMNEY FLUE page 6.Adverse weatherconditionsIn case of strong wind there can be a negative pressureto the chimney. Check it and start the stove up again.AL 9 - DOOROPENThe fire door is notcorrectly closedClose the fire door correctly and check if the gasketsare damaged. (In this case have it replaced by anAuthorized Technician).Fire door microswitchfaulty or out of order Replace the fire door microswitch.15.2 PROBLEM SOLVINGBefore of every testing and/or intervention of the Authorized Technician, the AutorizedTechnician personally has the duty to verify that the parameters of the electronic boardmeet those of the reference table you own.In case of doubts regarding the running of the stove please contact ONLY the AutorizedTechnician in order to avoid irreparable damages!