_ 18User manual LAM1006 / LAM1007Regulating the minimum flameAfter lighting the burners, turn the control knobto the minimum setting then remove the knob(this can easily be removed by applying gentlepressure).Using a small «terminal» type screwdriver theregulating screw can be adjusted as in imagebelow. Turning the screw clockwise reduces thegas flow, whilst turning it anticlockwise increasesthe flow - use this adjustment to obtain a flameof approximately 3 to 4mm in length and thenreplace the control knob.When the gas supply available is LPG - the screwto set the idle flame must be turned clockwise tothe end stop.When you have carried out the new gas regulation,replace the old gas rating plate on your appliancewith one (supplied with hob) suitable for the typeof gas for which it has been regulated.