3InstallationLed Power RGB can be installed in any positions.Attention, the IP65 protection rate does not allow to install the unit inplaces that can be flooded (for example under-ground box)The base of Led Power RGB has 4 blind holes. Open this holes ifnecessary. Distance of the holes: 172x136mm.Connect the projector to the power unit, using LEDs connection blockinside box.Unscrew upper screw to open the lid and access to display.Example of installationIf only one Led Power RGB is on stand alone mode the signal cable is not necessary.If the Led Power are driven by a DMX controller or Led Power Master drive other Led Power Slave, they need to be connectedtogether, with DMX signal cable, following the instructions of this manual.The DMX signal is generated by a DMX controller, the signal cable goes in and out from each power unit up to the last one.More Led Power RGB will execute the same scenes if the DMX addresses are the same (factory set is 1) or they can be drivenone by one if the DMX addresses are different from each other.In the pictures below, projector is Led Power RGBDefault mode 7C d: each projector uses 8 DMX channelsLed Power 1: DMX address 1 Led Power 2: DMX address 9 Led Power 3: DMX address 17……If the DMX controller is not switched on, the projectors can be in black-out mode, generate light at 15% (default setting) orgenerate light at 100%. Change this parameter at – DM.DE of menu.It is possible to use MASTER/SLAVE function: One projector (Master) functioning in stand alone mode with residentprograms and a group of projector (Slave) execute, thanks to dmx signal and signal cables, the same sequences of colours.The projectors can be fed from different power sources, it is not necessary to switch on the projectors at the same time.