214367 56 Revision A3.13 Attaching Hydraulics and Electrical ConnectionsThe procedure for attaching the header hydraulic and electrical connections depends on the windrower model.Refer to the appropriate procedure:• 3.13.1 Attaching Hydraulic and Electrical Components: M205 Windrowers, page 56• 3.13.2 Attaching Hydraulic and Electrical Components: M200 Windrowers, page 61• 3.13.3 Attaching Hydraulics and Electrical: M1240 Windrowers, page 673.13.1 Attaching Hydraulic and Electrical Components: M205 WindrowersDANGERTo avoid bodily injury or death from unexpected startup of the machine, always stop the engine andremove the key from the ignition before leaving the operator’s seat for any reason.NOTE:Factory-installed hard plumb connections are ideal for attaching an R85 disc header’s hydraulics on an M205windrower. If an auger header or draper header will also be used on a disc header-ready M205 windrower, quickcouplers can be ordered and installed to make switching between these headers easier 1.Routing hydraulic hose bundle from header to windrower:1005185AFigure 3.115: Windrower with Left Platform inOpen Position1. Move windrower left (cab-forward) platform (A) toOPEN position. For instructions, refer to the windroweroperator’s manual.ASSEMBLING THE HEADER1. Order two kits (MD #B5497) for use on an M205 windrower factory-configured for a disc header only. Order onekit (MD #B5497) for use on an M205 windrower factory-configured for auger and draper headers.