Contents - contact information
- safety information
- battery safety
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Introduction
- How an Inverter/Charger Works
- Features and Benefi ts
- Figure 1-2, Electrical Connection Points
- Figure 1-3, Left Side Features (MS2012, MS2812, MS2024, MS4024, MS4048)
- Figure 1-4, Left Side Features (MS2000 Series)
- Installation
- Figure 2-1, Simplifi ed Installation for Permanent Installations (MS Series)
- Figure 2-2, Simplifi ed Installation for Permanent Installations (MS2000)
- Locating the Inverter
- Mounting the Inverter
- Figure 2-4, MS Dimensions (MS2012, MS2812, MS2024, MS4024, MS4048)
- Figure 2-5, MS Dimensions (MS2000)
- Wiring the Inverter – General Requirements
- DC Wiring
- Figure 2-6, DC and Battery Temperature Sensor Wiring
- DC Wire Sizing
- DC Cable Connections
- Wiring the Battery Bank
- Battery Temperature Sensor Installation and Wiring
- Wiring the Inverter to the Battery Bank
- AC Wiring
- Recommended GFCI (Ground Fault Circuit Interruption) Outlets
- AC Conductor Wiring (MS2012, MS2812, MS2024, MS4024, & MS4048)
- AC Wiring Confi gurations (MS2012, MS2812, MS2024, MS4024, & MS4048)
- Figure 2-11, AC Wiring for Single In – Single Out (30 A) Confi gurations
- Figure 2-12, AC Wiring for Single In – Single Out (60 A) Confi gurations
- Figure 2-13, AC Wiring for Single In – Dual Out Confi gurations
- Figure 2-14, AC Wiring for Dual In – Single Out Confi gurations
- Figure 2-15, AC Wiring for Dual In – Dual Out Confi gurations
- AC Conductor Wiring (MS2000 models)
- AC Wiring Confi guration (MS2000 models)
- Figure 2-16, AC Wiring for MS2000 Models
- Figure 2-17, AC Wiring for MS2000-15B/-20B Models
- Grounding Inverters
- Sizing the Grounding Electrode Conductors
- Figure 2-20, Multiple Connections to DC Ground Rod (Method 2)
- System Bonding Jumper
- Grounding on Boats
- Neutral to Safety Ground Bonding
- Disabling the Neutral-to-Ground Connection
- Inverter Notifi cation Requirements
- Functional Test
- Figure 2-27, AC Voltage Checks
- Operation
- Figure 3-2, Power Flow – Inverter Mode (MS2000 models)
- Standby Mode
- Battery Charging
- Figure 3-7, Automatic 4-Stage Charging Graph
- Transfer Time
- Protection Circuitry Operation
- Inverter Startup
- Factory Default Values
- Inverter Fan Operation
- Maintenance and Troubleshooting
- Troubleshooting
- Resetting the Inverter
- Appendix A – Specifi cations and Optional Equipment
- A-2 Inverter Effi ciency
- A-4 Temperature and Inverter Output
- A-6 Optional Equipment and Accessories
- Appendix B – Battery Information
- B-5 Battery Bank Sizing Worksheet
- B-6 Battery Wiring Confi gurations
- Figure B-4, Battery Bank Wiring Examples (12-volt)
- Figure B-5, Battery Bank Wiring Examples (24-volt)
- Figure B-6, Battery Bank Wiring Examples (48-volt)
- Appendix C – Power Consumption & Output Waveforms
- Appendix D – Inverter/Charger Terminology
- Appendix E – Warranty & Service
|
Page 58© 2016 Sensata TechnologiesAppendix A – SpecificationsModels MS2000/12 MS2812 MS2024 MS4024 MS4048MS2012 (-15/-20B) MS4048-20BInverter SpecificationsInput battery voltage range 9.0 to 16.8 VDC 18.0 to 33.6 VDC 36.0 to 67.6 VDCAbsolute maximum DC input 25 VDC 35 VDCAC output voltage accuracy 120 VAC ±5% (≤ continuous power)Output frequency and accuracy 60 Hz ± 0.1 HzTotal Harmonic Distortion (THD) < 5%Continuous power output (at 25°C) 2000 VA 2800 VA 2000 VA 4000 VA 4000 VAContinuous AC output current 17 A 23 A 17 A 33 A1 msec surge current (amps AC) 50 70 75 120100 msec surge current (amps AC) 33 40 37 82 725 sec surge power (real watts) 3300 3900 2850 5800 850030 sec surge power (real watts) 3100 3800 2750 5400 57505 min surge power (real watts) 2800 3200 2700 4900 525030 min surge power (real watts) 2200 3000 2200 4500 4750Maximum continuous input current 267 ADC 373 ADC 133 ADC 267 ADC 133 ADCInverter efficiency (peak) 90.6% 90% 86% 93.7% 94.0%HBCO/HBCI (High Battery Cut Out/In) 16.8/16.5 VDC 33.6/33.0 VDC 67.6/66.7 VDCLBCO/LBCI (Low Battery Cut Out/In) 9.0 (adj)/12.5 VDC 18.0 (adj)/25.0 VDC 36.0 (adj)/50.0 VDCSeries stacking for 120/240 VAC No Yes, using two MS4024s, or two MS4048s*AC Relay transfer time (minimum) 16 msecPower consumption – searching <8 wattsPower consumption – inverting (no load) 25 watts 30 watts 25 wattsOutput waveform Pure Sine WaveCharger SpecificationsContinuous charger output at 25°C 100 ADC 125 ADC 60 ADC 105 ADC 60 ADCInput current for continuous rated output 15 AAC 18 AAC 7.9 AAC 29 AAC 30 AACCharger efficiency 85%AC input range (frequency/voltage) 50 to 70 Hz/ 60 to 140 VAC (120 VAC nominal)Power factor > 0.95General Features and CapabilitiesTransfer relay capability 30AAC max. each input (30AAC total on MS2000 models, 60AAC total on all other models)**Five-stage charging capability Bulk, Absorb, Float, Equalize (requires remote), and Battery Saver™Battery temperature compensation Standard with available temp sensor connected (battery temp 0 – 50°C)Internal cooling 0 to 120 cfm variable speed drive using dual 92 mm brushless DC fanOvercurrent protection with two overlapping circuitsOver-temperature protection on transformer, MOSFETS, and batteryCorrosion protection PCB’s conformal coated, powder coated chassis/top, and stainless steel fastenersSafety listings ETL listed to UL/cUL 458, UL 1741, CSA C22.2 No. 107.1-01, and meets KKK-A-1822E std.***Warranty 3 years parts and laborBranch-rated output circuit breakers Optional on MS2000 (15 or 20 amp breakers) or MS2012 (15 or 20 amp breakers)Environmental SpecificationsTemperature (Operating/Non-operating) -20°C to +60°C (-4°F to 140°F)/-40°C to +70°C (-40°F to 158°F)Operating humidity 0 to 95% RH non-condensingPhysical SpecificationsUnit dimensions (length x width x height) 13.75” x 12.65” x 8.0” (34.9 cm x 32.1 cm x 20.3 cm) [Height on MS2000 models is 7.0”/17.8 cm]Shipping dimensions (L x W x H) 19” x 17” x 13” (48.3 cm x 43.2 cm x 33 cm)Mounting Shelf or wall (vents not allowed to face downward unless ME-CB or MMP/MP is installed)Unit weight 42 lb (19.1 kg) 55 lb (24.9 kg) 41 lb (18.6 kg) 55 lb (24.9 kg) 55 lb (24.9 kg)Shipping weight 48 lb (21.8 kg) 62 lb (28.1 kg) 49 lb (22.2 kg) 62 lb (28.1 kg) 62 lb (28.1 kg)Max operating altitude 15,000’ (4570 m)* The MS4048-20B model is not series stackable.** The pass-thru capability on each leg of the – 15B and – 20B models is limited by the output breaker size on each output.*** MS2000 models ETL listed to UL/cUL 458, CSA C22.2 No. 107.1-01, and meet KKK-A-1822E standard.Specifications @ 25°C – Subject to change without notice.Appendix A – Specifications and Optional EquipmentA-1 Inverter/Charger Specifications
PreviousNext |