Operation Manual touchTymp MI 24 and MI 34 Version8107420 Rev. 6 66 03/09/20186.5 Electromagnetic Compatibility (EMC)Portable and mobile RF communications equipment can affect the touchTymp. Install and operate the touchTymp according to the EMCinformation presented in this section.The touchTymp has been tested for EMC emissions and immunity as a standalone touchTymp. Do not use the touchTymp adjacent to or stackedwith other electronic equipment. If adjacent or stacked use is necessary, the user should verify normal operation in the configuration.The use of accessories, transducers and cables other than those specified, with the exception of servicing parts sold by MAICO asreplacement parts for internal components, may result in increased EMISSIONS or decreased IMMUNITY of the device.Anyone connecting additional equipment is responsible for making sure the system complies with the IEC 60601-1-2 standard.Guidance and manufacturer’s declaration - electromagnetic emissionsThe touchTymp is intended for use in the electromagnetic environment specified below. The customer or the user of thetouchTymp should assure that it is used in such an environment.Emissions Test Compliance Electromagnetic environment - guidanceRF emissionsCISPR 11Group 1 The touchTymp uses RF energy only for its internal function.Therefore, its RF emissions are very low and are not likely to causeany interference in nearby electronic equipment.RF emissionsCISPR 11Class B The touchTymp is suitable for use in all commercial, industrial,business, and residential environments.Harmonic emissionsIEC 61000-3-2CompliesClass A CategoryVoltage fluctuations /flicker emissionsIEC 61000-3-3CompliesRecommended separation distances between portable and mobile RF communications equipment and the touchTymp.The touchTymp is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. Thecustomer or the user of the touchTymp can help prevent electromagnetic interferences by maintaining a minimum distance betweenportable and mobile RF communications equipment (transmitters) and the touchTymp as recommended below, according to themaximum output power of the communications equipment.Rated Maximum outputpower of transmitter[W]Separation distance according to frequency of transmitter[m]150 kHz to 80 MHzd = 1.17√𝑃80 MHz to 800 MHzd = 1.17√𝑃800 MHz to 2.5 GHzd = 2.23√𝑃0.01 0.12 0.12 0.230.1 0.37 0.37 0.741 1.17 1.17 2.3310 3.70 3.70 7.37100 11.70 11.70 23.30For transmitters rated at a maximum output power not listed above, the recommended separation distance d in meters (m) can beestimated using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of thetransmitter in watts (W) according to the transmitter manufacturer.Note 1 At 80 MHz and 800 MHZ, the higher frequency range applies.Note 2 These guidelines may not apply to all situations. Electromagnetic propagation is affected by absorption and reflection fromstructures, objects and people.Guidance and Manufacturer’s Declaration - Electromagnetic ImmunityThe touchTymp is intended for use in the electromagnetic environment specified below. The customer or the user of the touchTympshould assure that it is used in such an environment.Immunity Test IEC 60601 TestlevelCompliance ElectromagneticEnvironment-GuidanceElectrostatic Discharge(ESD)IEC 61000-4-2+6 kV contact+8 kV air+6 kV contact+8 kV airFloors should be wood, concrete orceramic tile. If floors are covered withsynthetic material, the relativehumidity should be greater than 30%.Electrical fasttransient/burstIEC61000-4-4+2 kV for power supply lines+1 kV for input/output lines+2 kV for power supply lines+1 kV for input/output linesMains power quality should be that ofa typical commercial or residentialenvironment.SurgeIEC 61000-4-5+1 kV differential mode+2 kV common mode+1 kV differential mode+2 kV common modeMains power quality should be that ofa typical commercial or residentialenvironment.Voltage dips, shortinterruptions and voltagevariations on powersupply linesIEC 61000-4-11< 5% UT(>95% dip in UT) for 0.5 cycle40% UT(60% dip in UT) for 5 cycles70% UT(30% dip in UT) for 25 cycles<5% UT(>95% dip in UT) for 5 sec< 5% UT (>95% dip in UT)for 0.5 cycle40% UT (60% dip in UT) for5 cycles70% UT (30% dip in UT) for25 cycles<5% UTMains power quality should be that ofa typical commercial or residentialenvironment. If the user of thetouchTymp requires continuedoperation during power mainsinterruptions, it is recommended thatthe touchTymp be powered from anuninterruptable power supply or itsbattery.Power frequency (50/60Hz)IEC 61000-4-83 A/m 3 A/m Power frequency magnetic fieldsshould be at levels characteristic of atypical location in a typical commercialor residential environment.Note: UT is the A.C. mains voltage prior to application of the test level.