L NAPCO Security Systems X GEM-X255 Installation InstructionsWI1093C 3/04 !Page 7SPECIFICATIONSGEM-X255Panel Dimensions: 12 3/8" x 13 7/8" x 3 Ω" (H x W x D) without coverOperating Temperature: 0-49∞C (32-120∞F)Input Power: 16.5VAC via CLASS 2 Plug-In 40VA or 50VA TransformerLoop Voltage: 10-13VDCLoop Current: 2.4mA with 2.2K Ohm end-of-line resistor (Model EOL2.2K); 5mA for 2-wire smoke-detector zonesLoop Resistance: 300 Ohm max.; 50 Ohm for 2-wire smoke-detector zonesRelay Outputs (Burglary; Reset; Aux): Wet, 12Vdc, 1.2A max.; Dry (cut related jumper for dry contacts; see Wiring Dia-gram), SPDT contacts 24Vdc, 2A, 0.6 PFAuxiliary Power Output: 12Vdc regulatedRemote Power Output: 12Vdc regulated (for keypads)Combined Standby Current (Remote Power + Aux. Power + Reset Relay Power): See following charts.Notes: (1) With 1 RBAT6 battery, GEM-X255 combined standby current + PS3002 standby current may not exceed 1.2A.(2) With 2 RBAT6 batteries, GEM-X255 combined standby current + alarm current may not exceed 1.9A.Standby Time: Residential Fire/Burglary & Commercial Burglary, 24 hours minimumEZM Module: GEM-EZM8: Input, 50mA (not including PGM output)PGM Output: 5mA, 12V Special ApplicationKeypad Current:GEM-RP1CAe2/GEM-K1CA: 100mA; 35mA if backlighting is disabled (cut W1, W2 & W3)PGM Output: 5mA, 12V Special ApplicationMaximum Number of Keypads: 15Maximum Wiring Length for each run (#22AWG): 1000' divided by total number of keypads and EZMs on runKeypad Dimensions: 4 º" x 5 æ" x 1" (H x W x D); 11.1cmORDERING INFORMATIONSystem ComponentsGEM-X255: Residential UL-Listed Burg Control Panel.GEM-RP1CAe2/GEM-K1CA: 32-Character LCD Burg & Residential Fire Keypad with 4 EOL Resistor SupervisedZones.TRANSFORMER RECHARGEABLEBATTERYPOWERSUPPLYGEM-X255 COMBINEDSTANDBY CURRENTGEM-X255ALARMCURRENTPS3002 POWERSUPPLYSTANDBYCURRENTSTANDBYTIMETRF11 (16.5 VAC, 40 VA) RBAT4 (12 VDC, 4 AH) N/A 750 mA 2.0 A N/A 4 HoursTRF11 (16.5 VAC, 40 VA) RBAT6 (12 VDC, 6 AH) N/A 750 mA 2.0 A N/A 6 HoursTRF11 (16.5 VAC, 40 VA) (3) RBAT6 (12 VDC, 6 AH) PS3002 (13.2 VDC, 1.9 A) 750 mA 1.9 A 1.2 A (1) 4 HoursTRF11 (16.5 VAC, 40 VA) (3) 2 RBAT6 (12 VDC, 6 AH) PS3002 (13.2 VDC, 1.9 A) 750 mA 1.9 A (2) 1.4 A 4 HoursRESIDENTIAL BURGLARY & COMMERCIAL BURGLARYTRANSFORMER RECHARGEABLEBATTERYGEM-X255COMBINEDSTANDBY CURRENTGEM-X255ALARMCURRENTSTANDBYTIMETRF11 (16.5 VAC, 40 VA) RBAT7 (12 VDC, 7 AH) 150 mA 650 mA 24 HoursRESIDENTIAL FIRE, COMBINATION RESIDENTIAL FIRE & BURGLARY