WI1372 XP-600 Installation InstructionsRemote ActivationUsing NAPCOís Quickloader Software(Version 3.26 or higher), follow theinstructions below:From the Status ScreenPress F6Select Miscellaneous ControlSelect Enable Signal Strength LoggingUploading Signal Strength Informationfrom the LogAfter approximately (2) two hours, re-establisha connection with the panel. Signal strengthlog information ranges from 1 to 10. Thelogging of signal strength should appearsimilar to the sample LOG below:Zone Features[00]Exit/Entry ZonesDelay allows exit and entry through an Exit/Entry Zone after the system is armedwithout setting off an immediate alarm. ExitDelay allows the user to leave the premisesafter arming. Entry Delay allows the usertime to enter and disarm. The entry delaymay be canceled by pressing a 4.[01]Home/Away with Delay ZonesZones that automatically bypass at theexpiration of the exit delay if the EXIT/ENTRY zone(s) are not violated. Zones ofthis type have a three (3) minute power-updelay, and do not display or cause an alarmif faulted when the system powers up.Pressing the b key cancels the 3 minutetimer.If Exit/Entry zone(s) are violated during theexit delay, zones programmed as Home/Away with Delay Zone(s) will have a fixed20-second entry delay, if violated before theExit/Entry zone.To eliminate this fixed 20-second entrydelay, also program zones as Exit/EntryFollower Zones [02].To return protection to zones of this type,press cb from the keypad or M orN from a Keyfob. Program the KeyfobAUX 1 or AUX 2 button for Full Set [81-7].[02]Exit/Entry Follower ZonesEntry Delay allows the user time to enterand disarm. Allows exit after the panel isarmed without setting off an immediatealarm and allows entry only if an Exit/EntryZone [00] has been violated first. Zones ofthis type have a three (3) minute power-updelay, and do not display or cause an alarmif faulted when the system powers up.Pressing the b key cancels the 3 minutetimer.Group Bypassing - Zones programmed asExit/Entry Follower Zones will be Groupbypassed if the c c is pressed whiledisarmed or within the Exit Delay.Auto Interior Bypassing - Also programzones as Home/Away with Delay Zone(s)[01] to automatically bypass at the expirationof the exit delay if the EXIT/ENTRY Zone(s)are not violated during the exit delay.[03]Auto-Bypass Reentry ZonesZones programmed as this zone type arepermitted to be faulted at the time of arming.Once the zone is restored, while the controlpanel is still armed, the zone willautomatically be unbypassed and anysubsequent violations of the zone will causeIf A0 is Entered during Exit Time, Home/Away withDelay Zones will be automatically bypassed, even if theExit/Entry Zone is violated. Easy Exit/Easy Arm [22-2] mustbe enabled.NOTE :07/24/97 17:44 QL: Full Program Uploaded07/24/97 17:42 QL: Technical Connection(callback) Technician 207/24/97 15:23 Transmitter Status: GEM_SMK 1(7A0DB5): SS=707/24/97 15:13 Transmitter Status: GEM_SMK 2(768447): SS=807/24/97 15:13 Transmitter Status: Zone 2, SS=607/24/97 14:27 Trouble: RF Link, GEM_RECV 107/24/97 14:25 Panic: Keypad07/24/97 14:25 Panic: Keyfob 1(933780) SS=807/24/97 14:25 Dealer Program Mode Entered07/24/97 14:24 Instant: Keyfob 1(933780) SS=807/24/97 14:24 QL: Connection Terminated (10MIN T/O)07/24/97 13:13 QL: Full Program Downloaded06/24/97 12:06 Open: User 206/24/97 12:06 Close: EasyArm06/24/97 11:55 Trouble Restore: Low Battery,GEM_SMK 2(768447) SS=806/24/97 10:21 Transmitter Status: GEM_SMK(7A0DB5): SS=6