B-6 Management Workstation ApplicationConfiguring Server BIOS SetupTo use MWA, you must configure the server's BIOS with three specific settingsenabled. These settings take place in Advanced Menu and the Hardware Menuof the BIOS Setup. (Refer to Chapter 3, “Configuring Your System,” for BIOSSetup information.) The following table shows the settings that must be enabledto use MWA.Menu Parameter Name Required Setting forMWAADVANCED MENUAdvancedPress Enter for menu.ROMPilot Support EnabledPeripheral ConfigurationPress Enter for menu.LAN controller EnabledSYSTEM HARDWARE MENUWake On LAN EnabledInstalling MWA on the Management PCTo Install MWA on the management PC perform the following procedure.1. Start Windows95 / Windows 98 / or Windows NT on the management PC.2. Insert the EXPRESSB UILDER CD into the PC CD-ROM drive.3. Using Explorer, execute "setup.exe" in MWA folder of the CD-ROM. MWAinstaller will start.4. Follow MWA installer instructions.Note: MWA will be registered in the Startup folder afterinstallation, and started automatically when an OS start (Login) is initiated.Registering SG Information on MWAIn order for MWA to connect with a server, the server system generationinformation (SG) must be set and registered on MWA.In this procedure SG information is registered on MWA from the server SystemGeneration diskette (SG) created in the section Creating a Server SystemGeneration diskette (SG).1. Run MWA on the management PC and select the New SG command fromFile menu. The Create a New Server dialog box displays.