English.1EnglishPower Cord Important InformationCAUTION: Please use the power cord provided with this display in accordance with the table below. If a power cord is not supplied withthis equipment, please contact your supplier. For all other cases, please use a power cord that matches the AC voltage of the poweroutlet and has been approved by and complies with the safety standard of your particular country.When you use this Display in North America, you should use a North America Hospital Grade power cord.Intended UseThe MD205MG-1 grayscale display is intended to be used for displaying and viewing of digital images for diagnosis, including digitalmammography, by trained physicians.North America CustomersGrounding reliability can only be achieved when the equipment is connected to an equivalent receptacle marked “Hospital Only” or“Hospital Grade”.That signal input port need to be connected properly and that any unused signal input port shall not be accessible for the patient tocontact in the patient area after the LCD is integrated into a medical system.European CustomersUnpacking, Installation and calibration of this display should only be done by authorized and trained personnel.Any installation done by a non-authorized person is done under his own risk and we accept no responsibility inany device malfunctioning.Medical ImagingThe NEC MD205MG-1 is designed for 5-megapixel (2048 x 2560) grayscale medical imaging. This display comes fully tuned with asetting for gamma correction that complies with the DICOM Part 14 Standard.Microsoft and Windows are registered trademarks of Microsoft Corporation in the United States and other countries.All other brands and product names are trademarks or registered trademarks of their respective owners.WARNINGTO PREVENT FIRE OR SHOCK HAZARDS, DO NOT EXPOSE THIS UNIT TO RAIN OR MOISTURE. ALSO, DO NOT USE THIS UNIT'S POLARIZED PLUG WITHAN EXTENSION CORD RECEPTACLE OR OTHER OUTLETS UNLESS THE PRONGS CAN BE FULLY INSERTED.REFRAIN FROM OPENING THE CABINET AS THERE ARE HIGH VOLTAGE COMPONENTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.TO REDUCE THE RISK OF ELECTRIC SHOCK, MAKE SURE POWER CORD IS UNPLUGGED FROM WALL SOCKET. TO FULLY DISENGAGE THE POWERTO THE UNIT, PLEASE DISCONNECT THE POWER CORD FROM THE AC OUTLET. DO NOT REMOVE COVER (OR BACK). NO USER SERVICEABLEPARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.This symbol warns user that uninsulated voltage within the unit may have sufficient magnitude to cause electric shock.Therefore, it is dangerous to make any kind of contact with any part inside this unit.This symbol alerts the user that important literature concerning the operation and maintenance of this unit has been included.Therefore, it should be read carefully in order to avoid any problems.To guarantee the display performance as specified, it must only be used in conjunction with NEC approved display controllers.The MD205MG-1 cannot be used for a life-support system.This unit is designed as component of a final system which is in compliance to IEC60601-1-1 requirements.Federal law restricts this device to sale by or on the order of a (licensed healthcare practitioner).CAUTIONCAUTION:Plug Type European Continental ChineseNorth AmericaHospital GradeJapanese(for Japanese Market only)Plug ShapeCountryVoltage 120 230 220 100U.S.A./Canada EU (except U.K.) China Japan(green dotand tag label)U.K.230U.K.01_MD205MG-1_INSTALL_EN.P65 7/5/08, 10:09 AM1