CHAPTER 2 INSTALLATION19-inch Rack Mounting InstallationNEAX2000 IVS2 Installation Procedure ManualND-70928 (E), Issue 1.0 Page 7519-inch Rack Mounting Installation• Check the site for installing the PBX with the work drawing to verify thatthe required floor space is ensured and that service entrances and ductsfor trunk/extension cables, power cables and grounding conductorshave been properly worked at correct positions.See Figure 2-7 and Figure 2-8.• Detach the SIDE COVER and SIDE PANEL of the Module for 19” RACKBRACKET (A) mounting. For 19” RACK BRACKET (B), this procedureis not required. See “Detaching SIDE COVER/SIDE PANEL” onPage 76.• Mount the 19” RACK BRACKET (A) to the PIM. See “Connection of 19”RACK BRACKET (A)” on Page 78.• Mount the PIM with the 19” RACK BRACKET (A) to the 19-inch RACK.See “Mounting PIM to 19-inch RACK” on Page 79.• Mount the 19” RACK BRACKET (B) to the bottom-stack PIM. See “Con-nection of 19” RACK BRACKET (B)” on Page 80.• Mount the 19” RACK BRACKET (A) to the top-stack PIM. See “Connec-tion of 19” RACK BRACKET (A)” on Page 78.• Mount the PIMs with the 19” RACK BRACKET (A) and (B) to the 19-inchRACK. See Figure 2-25.• Carefully review every step above to ensure that all necessary screwsare properly placed and tightened.StartCheckupbefore installationOne PIMMultiple-PIMCheckingDetachingSide Cover/Side PanelEndConfigurationConfiguration