CHAPTER 2 INSTALLATIONProcedure for Unplugging/Plugging Circuit CardsNEAX2000 IVS2 Installation Procedure ManualND-70928 (E), Issue 1.0 Page 41Procedure for Unplugging/Plugging Circuit CardsWhen removing a circuit card from the PIM or when mounting a circuit card in the PIM, follow theprocedure in Table 2-1.Table 2-1 Procedure for Unplugging/Plugging Circuit CardsCIRCUIT CARD PROCEDURE CONDITIONPLUG UNPLUG• PN-CP14 (MP)• PZ-PW121 (AC/DC PWR)• PZ-PW122 (DC/DC PWR)• PZ-M537 (EXTMEM)(1) Power off(2) Plug in(3) Power on(1) Power off(2) Unplug(3) Power onThese circuit cards must beplugged in or unplugged onlywith power off to prevent dam-age to the card or other systemcircuitry.• PN-AP00-A (DBM)• PN-AP00-B (AP00)• PN-AP01 (AP01)• PN-BRTA (BRT)• PN-2BRTC (BRT)• PN-CP15 (FP)• PN-DAIA (DAI)• PN-DAIB (DAI)• PN-DAIC (DAI)• PN-DAID (DAI)• PN-DAIE (DAI)• PN-DAIF (DAI)• PN-24DTA-C (DTI)• PN-30DTC-A (DTI)• PN-IPTA (IPT)• PN-24PRTA (PRT)• PN-PW00 (EXTPWR)• PN-4RSTB (MFR)• PN-4RSTC (CIR)• PN-SC00 (CCH)• PN-SC01 (DCH)• PN-SC03 (ICH)• PN-SC03-A (CSH)• PZ-M542 (CONN)• PZ-M557 (CONN)• PZ-VM00-M (VM)• PZ-VM01 (VM)(1) Power offor MBswitch on(2) Plug in(3) Power onor MBswitch off(1) Power offor MBswitch on(2) Unplug(3) Power onThese circuit cards must beplugged in or unplugged underMake Busy condition or poweroff to prevent damage to thecard or other system circuitry.