CHAPTER 2 INSTALLATIONSystem InitializationNEAX2000 IVS2 Installation Procedure ManualND-70928 (E), Issue 1.0 Page 201SYSTEM INITIALIZATIONThere are two methods for System Initialization. The first method is to Clear AllData, except LEN000 as a CAT terminal, then program the System Data. Thesecond method is to use the Resident System Program, which causes the sys-tem to configure itself automatically to the default settings, wherever the line/trunk cards are installed.NOTE 1: See CHAPTER 3 for MP switch settings. Page 209NOTE 2: Refer to the Command Manual for default settings on the Resident System Program.All Clear, Except LEN000 CATSTEP 1: Turn on the “SW1” switch on all the PZ-PW121 cards.- The “ON” lamp must be lit on all the PZ-PW121 cards.STEP 2: On the MP Card, set SW3 to “B” and press SW1.STEP 3: When the “MN” lamp on the system is lit, set SW3 to the “0” position and press SW1.- The operating mode has been changed to the ON LINE mode.Resident System ProgramSTEP 1: Mount the line/trunk cards into PIM.STEP 2: Turn on the “SW1” switch on all the PZ-PW121 cards.- The “ON” lamp must be lit on all the PZ-PW121 cards.STEP 3: On the MP card, set SW3 to “C” and press SW1.- After 30 to 40 seconds, the “MN” lamp turns on.- The system has loaded the Resident System Program.NOTE: If the “MJ” lamp is lit, repeat Step 3.STEP 4: On the MP card, set SW3 to the “0” position and press SW1.- The operating mode has been changed to the ON LINE mode.ATTENTIONContentsStatic SensitiveHandlingPrecautions Required