Program 15 : Extension, Basic Setup15-14 : Programmable One-Touch KeysLevel:SB(This Program is available for V2.0 or higher) (SL1000)DescriptionUse Program 15-14 : Programmable One-Touch Keys to define the One-Touch key data for eachmultiline terminal.For each SL1000/SL1100 Wireless telephone to use the Transfer When Out of Range feature, enterthe destination number (up to 36 digits) and name (up to 12 characters) into One-Touch bin 10. Makesure to add any required trunk access codes for outside numbers. If this bin information is changedeither through 15-14-01 or through user programming, the destination for the transferred calls is alsochanged.Input DataExtension Number Maximum eight digitsKey Number 01 ~ 10ItemNo.Item Input Data Description Default01 Dial Data Maximum of 36 digits (0~ 9, *, #, @, P, R)@ = Wait for Answer Su-pervision - ISDN trunksonlyP = Pause - AnalogTrunk OnlyR = Hook flash - AnalogTrunk OnlyIf PRG 15-02-60 is set to a (0) then thestations personal speed dial entries areprogrammed here.Per key number (1 ~ 10) assign the tele-phone number that is to be called whenthe bin is accessed.No Setting02 Name Maximum of 12 charac-tersPer key number (1 ~ 10) assign a name tobe used when searching through the direc-tory.If a name is not assigned for a speed dialbin the speed dial entry will not be listed inthe directory.No SettingConditionsNoneFeature Cross ReferenceNoneSL1000/SL1100 ISSUE 3.012-160 Program 15 : Extension, Basic SetupProgram15