466. Maintenance2. Use a Philips screwdriver to push and release the tab.Push up and remove the lamp cover.CatchPhilipsscrewdriverReplacing the LampAfter your lamp has been operating for 3000 hours (up to 4000 hours in Eco mode) or longer, the LAMP indicator in thecabinet will blink red and the message “The lamp has reached the end of its usable life. Please replace the lamp.”will appear. Even though the lamp may still be working, replace it at 3000 (up to 4000 hours in Eco mode) hours tomaintain optimal projector performance. After replacing the lamp, be sure to clear the lamp hour meter. See page 43.CAUTION• DO NOT TOUCH THE LAMP immediately after it has been used. It will be extremely hot. Turn the projector off,wait 30 seconds, turn off the main power switch and then disconnect the power cable. Allow at least one hourfor the lamp to cool before handling.• DO NOT REMOVE ANY SCREWS except two lamp case screws. You could receive an electric shock.• Do not break the glass on the lamp housing.Keep finger prints off the glass surface on the lamp housing. Leaving finger prints in the glass surface mightcause an unwanted shadow and poor picture quality.• The projector will turn off and go into standby mode after 3100 (up to 4100 hours in Eco mode) hours of service.If this happens, be sure to replace the lamp. If you continue to use the lamp after 3000 hours (up to 4000 hoursin Eco mode) of use, the lamp bulb may shatter, and pieces of glass may be scattered in the lamp case. Do nottouch them as the pieces of glass may cause injury. If this happens, contact your NEC dealer for lamp replace-ment.To replace the lamp:Optional lamp and tools needed for replacement:• Replacement lamp VT70LP• Phillips screwdriver or equivalent1. Place the projector on a soft cloth and turn it over to access the lamp cover on the bottom.