APPENDIX APLC CONTROLLERA - 8The Status 1 screen shows the condition of the Hydraulic Pressure Switch and the Top ofStroke Limit Switch. If one or both of the TOS Shear Limit Switches are not activatedthe TOS Shear Limit Switch light will be on. Refer to the Shear section in the machinemanual for limit switch adjustment.If the motor is not on or if the pressure switch is not activated then the Hydraulic Motorlight will be on.The Status screen lists the Encoder Wheel Circumference. This value is changedautomatically when the controller is calibrated. The Stop Reaction Distance is alsoautomatically changed by the controller as the machine runs. In order to reset thesevalues, press the Restore Defaults button. NOTE: Calibration should be initiatedfollowing the defaults restore. The Total Material Ran through the machine with thecontroller on is shown on this screen. The Total Material Ran can be reset by pressingthe Reset button. If the security is turned on, the password will be required to reset theTotal Material Ran.Press Back to return to the Setup Screen.Security:From the Setup screen press the Security Settings button to enter the security screen. Thedefault password is: 1234.Figure 96: Security ScreenIf the security is turned on, the password will be required to change the stored coillengths and colors or to reset the Total Material Ran value (totalizer). If security is turnedoff, no password is needed to make changes to these values. With security turned off theSecurity screen displays the current password which can be changed by entering a newpassword and pressing the enter button. Once this is done, the new password will beneeded to make any changes to the coil lengths and colors or to reset the Total MaterialRan.