Table 3-53. Tx Event FIFO Element Description (continued)E1 Bits 31:24 MM[7:0]: Message MarkerCopied from Tx Buffer into Tx Event FIFO element for identification of Tx message status.E1 Bit 23:22 ET[1:0]: Event Type00 Reserved01 Tx event10 Transmission in spite of cancellation (always set for transmissions in DAR mode)11 ReservedE1 Bit 21 EDL: Extended Data Length0 Standard frame format1 CAN FD frame format (new DLC-coding and CRC)E1 Bit 20 BRS: Bit Rate Switch0 Frame transmitted without bit rate switching1 Frame transmitted with bit rate switchingE1 Bits 19:16 DLC[3:0]: Data Length Code0-8 CAN + CAN FD: Frame with 0-8 data bytes transmitted9-15 CAN: Frame with 8 data bytes transmitted9-15 CAN FD: frame with 12/16/20/24/32/48/64 data bytes transmittedE1 Bits 15:0 TXTS[15:0]: Tx TimestampTimestamp Counter value captured on start of frame transmission. Resolution depending onconfiguration of the Timestamp Counter Prescaler TSCC.TCP.3.4.4 Standard Message ID Filter ElementUp to 128 filter elements can be configured for 11-bit standard IDs. When accessing aStandard Message ID Filter element, its address is the Filter List Standard Start AddressSIDFC[FLSSA] plus the index of the filter element (0…127).Table 3-54. Standard Message ID Filter Element31 24 23 16 15 8 7 0S0SFT[1:0]SFEC[2:0] SFID1[10:0] res SFID2[10:0]Message RAMMPC5777C Reference Manual Addendum, Rev. 1, 12/201584 Freescale Semiconductor, Inc.