W415-1793 / A / 05.07.18EN8general informationThis illustration is for reference only. Refer to the rating plate on the appliance for accurate information.1.3 rating plate informationThe rating plate must remain with the appliance at all times. It must not be removed.note:1.4 mobile home installationThis appliance must be installed in accordance with the manufacturer’s instructions and the ManufacturedHome Construction and Safety Standard, Title 24 CFR, Part 3280, in the United States or the Mobile HomeStandard, CAN/CSA Z240 MH Series, in Canada. This appliance is only for use with the type(s) of gasindicated on the rating plate.This mobile/manufactured home listed appliance comes factory equipped with a means to secure the appliance. Builtin appliances are equipped with 1/4” (6.4mm) diameter holes located in the front left and right corners of the base.Use appropriate fasteners, inserted through the holes in the base to secure. For free standing products contact yourlocal authorized dealer / distributor for the appropriate securing kit. For mobile home installations, the appliance mustbe fastened in place. It is recommended that the appliance be secured in all installations. Always turn off the pilot andthe fuel supply at the source, prior to moving the mobile home. After moving the mobile home and prior to lighting theappliance, ensure that the logs are positioned correctly.This appliance is certified to be installed in an aftermarket permanently located, manufactured (mobile) home,where not prohibited by local codes.This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertiblefor use with other gases, unless a certified kit is used.Conversion KitsThis appliance is field convertible between Natural Gas (NG) and Propane (P).To convert from one gas to another, consult your Authorized dealer/distributor.20.1note:Conversion kits are not available for Vent Free appliances.MAX SIZE: 8.5" X 4.75"HOLE TO BE 0.250"ØMATERIAL: CLASS III A-2, PERMANENT LABEL, WATERPROOF, .010MIL VELVET MATTE LEXAN AND/OR .050 HI-TEMP POLYESTER, CAPABLE OF WITHSTANDING A MAXIMUMTEMPERATURE OF 175°F (79°C).MIN. LETTERING FOR "NOT FOR USE WITH SOLID FUEL. ", "NE CONVIENT PAS AUX COMBUSTIBLES SOLIDES. " TO BE 10 POINT VOGUE, BOLD FACE, UPPER CASE AND 2POINT LEADING SPACING OR EQUIVALENT.BLACK LETTERING ON WHITE BACKGROUND.SERIAL NUMBERS TO BE ASCENDING FROM GX36 231140Certified to Canadian and American National Standards: CSA 2.22-2016 / ANSI Z21.50-2016 for Vented Decorative Gas AppliancesCertifié selon les normes Nationales Canadiennes et Américaines: CSA 2.22-2016 / ANSI Z21.50-2016 pour les Appareils à gaz décoratif à évacuationDirect vent, vented gas fireplaces. Approved for bedroom, bathroom and bed-sitting room installation. Suitable for mobile home installation, if installed in accordance with the currentstandard CAN / CSA Z240MH Series gas equipped mobile homes in Canada, or, in the United States, the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part3280. When this US Standard is not applicable, use the Standard for Fire Safety Criteria for Manufactured Home Installations, Sites and Communities, ANSI / NFPA 501A. This appliancemust be installed in accordance with local codes, if any; if none, follow the current ANSI Z223.1 or CSA B149. For use with barrier W565-0144. Follow installation instructions.Foyer à gaz ventilé. Homologué pour installation dans une chambre à coucher, une salle de bain et un studio. Approprié pour installation dans une maison mobile si son installationconforme aux exigences de la norme CAN / CSA Z240MH Séries de maisons mobile équipées au gaz en vigueur au Canada, ou, aux États-Unis selon la norme 24 CFR, Part 3280,Manufactured Home Construction and Safety Standard. Dans le cas ou cette norme d’États-Unis n’est pas pertinentes, utiliser la norme NFPA 501A, Fire Safety Criteria for ManufacturedHome Installations, Sites and Communities. Installer l’appareil selon les codes ou règlements locaux ou, en l’absence de tels règlements, selon les codes d’installation ANSI Z223.1 ouCSA B149 en vigueur. Utiliser uniquement avec l’écran W565-0144. Suivre les instructions d’installation.9700539 (WSL) 4001658 (NAC) 4001657 (NGZ) 4001659 (WUSA)WOLF STEEL LTD. 24 Napoleon Road, Barrie, ON, L4M 0G8 CanadaGX70NT CX70NT GX70PT CX70PTGX70NTE CX70NTE GX70PTE CX70PTEMODEL / MODÈLEAltitudeInputReduced InputP4ÉlévationAlimentationAlimentation RéduiteP4Manifold Pressure: 3.5” w.c. (NG)Minimum Supply Pressure: 4.5” w.c. (NG)Maximum Supply Pressure: 7”* w.c. (NG)Pression au Collecteur: 3,5” d’une colonne d’eau (GN)Pression d’Alimentation Min.: 4,5” d’une colonne d’eau (GN)Pression d’Alimentation Max.: 7”* d’une colonne d’eau (GN)*Maximum inlet pressure not to exceed 13”.Manifold Pressure: 10” w.c. (P)Minimum Supply Pressure: 11” w.c. (P)Maximum Supply Pressure: 13”* w.c. (P)Pression au Collecteur: 10” d’une colonne d’eau (P)Pression d’Alimentation Min.: 11” d’une colonne d’eau (P)Pression d’Alimentation Max.: 13”* d’une colonne d’eau (P)*Pression d’alimentation maximale ne devait pas dépasser 13”.0-4500ft (0-1370m)Minimum clearance to combustible materials:Sides & back: per stand spacers for framing and finishingmaterials. For non-combustible framing and finishing materials,see installation manual.Top 6 3/4”Floor 0”Sides 3”Back 0”Vent top 3”Vent sides & bottom 1”Mantel 10 1/2”*Dégagements minimaux des matériaux combustibles:Côtés et arrière: selon les espaceurs de dégagements pour lesmatériaux d’ossature selon le manual du propriétaire pour lesmatériaux de finition.Dessus 6 3/4”Plancher 0”Côtés 3”Arrière 0”Dessus du conduit d’évent 3”Côtés et dessous du conduit d’évent 1”Tablette 10 1/2”*Recessed depth 18” Profondeur d’encastré 18”*Maximum horizontal extension: 2”. See installation manual forgreater extensions, minimum vent lengths and maximum ventlengths.*L’extension horizontale maximale: 2”. Référez au manuel d’installationpour des extensions plus grandes, les longueurs d’évacuation minimaux etmaximum.InserttestingagencylogoSerial Number / N° de Série:W385-2070 / DTITLE: LABEL, RATING PLATE GX36(N)TR(E) / GX36(P)TR(E)REVISION: B: Updated rates + P4 efficiency + added energy efficiency label || 04.09.18_DWG#: W385-2070DATE: 07.14.15WOLF STEEL LTD.REFERENCE# 161746GX70WARNING : Do not add any material to the appliance which will come in contact with theflames, other than that supplied by the manufacturer with the appliance.AVERTISSEMENT : N’ajoutez pas à cet appareil aucun matériau devant entretiencontact avec les flammes autre que celui qui est fourni avec cet appareil par le fabricant.The appliance must be vented using the appropriate Napoleon vent kits. See installationmanual for venting specifications. Proper reinstallation and resealing is necessary after servicingthe vent-air intake system.L’appareil doit être ventilé à l’aide de l’ensemble d’évacuation propre à Napoleon. Référez aumanuel d’installation pour les spécifications d’évacuation. Il est nécessaire de bien réinstaller etresceller l’évacuation après avoir executer l’entertien du système de prise d’air.Electrical rating: 115V, 60HZ. Less than 12 amperes.Spécifications électriques: 115V, 60HZ. Moins de 12 ampère.35,000 BTU/h21,000 BTU/h60.0%32,000 BTU/h26,000 BTU/h60.2%VENTED DECORATIVE GAS APPLIANCE: NOT A SOURCE OFHEAT, NOT INTENDED FOR USE AS A HEATING APPLIANCE,NOT FOR USE WITH SOLID FUEL.APPAREIL À GAZ DÉCORATIF À ÉVACUATION: N’EST PASUNE SOURCE DE CHALEUR; N’EST PAS DESTINÉ À ÈTREUTILISÉ COMME UN APPAREIL DE CHAUFFAGE; NECONVIENT PAS AUX COMBUSTIBLES SOLIDES.FOR USE WITH GLASS DOORS CERTIFIED WITH THIS APPLIANCE ONLY.POUR UTILISATION UNIQUEMENT AVEC LES PORTES EN VERRECERTIFIÉES AVEC L’APPAREIL.SAMPLE