ENW415-1299 / B / 06.16.14155.0 FINISHING! WARNINGPOWER SUPPLY SERVICE MUST BE COMPLETED PRIOR TO FINISHING TO AVOIDRECONSTRUCTION.HEAT VENTS AND AIR OPENINGS CANNOT BE COVERED IN ANY CIRCUMSTANCES.5.1 GLASS DOOR REMOVAL AND INSTALLATION! WARNINGTHE DOOR LATCHES ARE PART OF A SAFETY SYSTEM AND MUST BE PROPERLY ENGAGED. DONOT OPERATE THE APPLIANCE WITH LATCHES DISENGAGED.FACING AND/OR FINISHING MATERIALS MUST NOT INTERFERE WITH AIR FLOW THROUGH AIROPENINGS, LOUVRES OPENINGS, OPERATION OF LOUVRES OR DOORS OR ACCESS FORSERVICE. OBSERVE ALL CLEARANCES WHEN APPLYING COMBUSTIBLE MATERIALS.BEFORE DOOR IS REMOVED TURN THE APPLIANCE OFF AND WAIT UNTIL APPLIANCE IS COOL TOTHE TOUCH. DOORS ARE HEAVY AND FRAGILE SO HANDLE WITH CARE.75.1A. To remove the glass door, swing the top two latches to release the door. The door will hang slightlyon the the safety catch wire. NOTE: Pushing in on the door, will make the latch swing easier.B. Place one hand on the glass door while removing the screw from the catch wire. Allow the door topivot slightly, hold the sides with both hands while lifting the door out of the unit.C. To install the glass door, simply place the door on the holding pins on the bottom frame of the unit.Install the screw into the safety catch wire, slightly push the glass door into the frame and latch itsecure with the two top latches.SAFETYCATCH WIRESCREWLATCH* ILLUSTRATED WITH LATCHES VISIBLELOCKOPEN