18W415-1539 / A / 04.19.16ENENFor optimum performance it is recommended that all horizontal runs have a minimum of 1/4" (6mm)rise per foot using flexible venting. For safe and proper operation of the appliance, follow the ventinginstructions exactly.! WARNINGENSURE TO UNPACK ALL LOOSE MATERIALS FROM INSIDE THE FIREBOX PRIOR TO HOOKING UPTHE GAS AND ELECTRICAL SUPPLY.IF YOUR APPLIANCE IS SUPPLIED WITH A REMOTE ENSURE THE REMOTE RECEIVER IS IN THE“OFF” POSITION PRIOR TO HOOKING UP THE GAS AND ELECTRICAL SUPPLY TO THE APPLIANCE.FOR SAFE AND PROPER OPERATION OF THE APPLIANCE, FOLLOW THE VENTING INSTRUCTIONSEXACTLY.ALL INNER EXHAUST AND OUTER INTAKE VENT PIPE JOINTS MAY BE SEALED USING EITHER REDRTV HIGH TEMP SILICONE SEALANT W573-0002 (NOT SUPPLIED) OR BLACK HIGH TEMP MILL PACW573-0007 (NOT SUPPLIED) WITH THE EXCEPTION OF THE APPLIANCE EXHAUST FLUE COLLARWHICH MUST BE SEALED USING MILL PAC.IF USING PIPE CLAMPS TO CONNECT VENT COMPONENTS, A MINIMUM OF 3 SCREWS MUST ALSOBE USED TO ENSURE THE CONNECTION CANNOT SLIP OFF.DO NOT CLAMP THE FLEXIBLE VENT PIPE.RISK OF FIRE, EXPLOSION OR ASPHYXIATION. IMPROPER SUPPORT OF THE ENTIRE VENTINGSYSTEM MAY ALLOW VENT TO SAG AND SEPARATE. USE VENT RUN SUPPORTS AND CONNECTVENT SECTIONS PER INSTALLATION INSTRUCTIONS.RISK OF FIRE, DO NOT ALLOW LOOSE MATERIALS OR INSULATION TO TOUCH THE VENT PIPE.REMOVE INSULATION TO ALLOW FOR THE INSTALLATION OF THE ATTIC SHIELD AND TOMAINTAIN CLEARANCES TO COMBUSTIBLES.68.2C! WARNINGDO NOT FILL THE SPACE BETWEEN THE VENT PIPE AND ENCLOSURE WITH ANY TYPE OFMATERIAL. DO NOT PACK INSULATION OR COMBUSTIBLES BETWEEN CEILING FIRESTOPS.ALWAYS MAINTAIN SPECIFIED CLEARANCES AROUND VENTING AND FIRESTOP SYSTEMS.INSTALL WALL SHIELDS AND FIRESTOPS AS SPECIFIED. FAILURE TO KEEP INSULATION OROTHER MATERIALS AWAY FROM VENT PIPE MAY CAUSE FIRE.70.14.0 INSTALLATION4.1 WALL AND CEILING PROTECTION