W415-0702 / B / 04.04.12338.5 CONTROLS8.4 LIGHTING INSTRUCTIONSAfter filling the hopper with pellets, switch the control to manual so that you have full control of the applianceuntil you have familiarized yourself with its functions.Do not try to operate your appliance with the viewing door or hopper lid open. Safety switches will disable thepellet feed auger.A. Press the "ON/OFF" button "ON" to initiate the ignition cycle.B. Once the ignition cycle has ended (approximately 12 to 15 minutes) adjustments can be made to thecontrol.AUTO / T-STAT / MANUALThis switch is used to select the operating mode.MANUAL: Sliding the switch down to manual will allow you to manually select the heat and blowersettings. In manual mode the heater will run at your desired settings indefinitely, until you manually turnthe heater off or the heater runs out of pellets.T-STAT: If you would like to have your heater operate using a thermostat, slide the switch to the middleposition (T-STAT). In T-STAT mode the remote thermostat will control the heat output by alternatingbetween the lowest heat level and the preset heat level. When the thermostat setting is satisfied theheater will default to the lowest heat level.AUTO: Slide the switch to the top position (AUTO). Similar to T-STAT mode, auto operates using athermostat. The difference being if the thermostat does not call for heat in a 60 minute period theheater will turn off completely. When the thermostat does call for heat, it will initiate a start-up cycle.This operating mode is recommended for the spring and fall season, as the heater is only requiredperiodically.AUGERFEEDONOFFPOWERAUGERAUTOT-STATMANUALHEAT FAN+($7 02'(15RED LIGHTSSolid- Indicates set feed rates- When making a fanadjustment, light will indicatefan speed temporarily andreturn to heat setting.Flashing- Indicates an operation failureHEAT ADJUSTMENTIncreases or decreases the heatlevel.AUGER FEEDSpeed feeding of pellets into theburn pot.RED LIGHTStart up CycleGREEN LIGHTSolid- Normal operating modeFlashing- Idling at lowest heat level.AMBER LIGHTAuger is turning.OPERATING MODESets the heater’s operating mode.FAN ADJUSTMENTIncreases or decreases the speedof the convection fan.ON / OFFUsed to turn the heater on or off.