W415-1676 / B / 10.26.1716EN4.0 INSTALLATIONNEVER INSTALL A SINGLE WALL SLIP SECTION OR SMOKE PIPE IN A CHASE STRUCTURE.THE HIGHER TEMPERATURE OF THIS SINGLE WALL PIPE MAY RADIATE SUFFICIENT HEAT TOCOMBUSTIBLE CHASE MATERIALS TO CAUSE A FIRE.TO AVOID DANGER OF FIRE, ALL INSTRUCTIONS MUST BE STRICTLY FOLLOWED, INCLUDINGTHE PROVISION OF AIR SPACE CLEARANCE BETWEEN CHIMNEY SYSTEM AND ENCLOSURE. TOPROTECT AGAINST THE EFFECTS OF CORROSION ON THOSE PARTS EXPOSED TO THE WEATHER,WE RECOMMEND THAT THE CHASE TOP BE PAINTED WITH A RUST-RESISTANT PAINT.MAINTAIN A MINIMUM 2" (51mm) AIR CLEARANCE TO ALL PARTS OF THE CHIMNEY SYSTEM ATALL TIMES. FAILURE TO MAINTAIN THIS 2" (51mm) AIR CLEARANCE WILL CAUSE A STRUCTUREFIRE.DETAILED INSTRUCTIONS FOR INSTALLATION OF THE CHASE TOP, STORM COLLAR ANDTERMINATION CAP ARE PACKAGED WITH THESE PARTS.FIRESTOP SPACERS MUST BE USED WHENEVER THE CHIMNEY PENETRATES A CEILING/FLOORAREA.THE CHIMNEY MUST BE SOUND AND FREE OF CRACKS. CLEAN YOUR CHIMNEY A MINIMUM OF TWICEA YEAR AND AS REQUIRED.4.1 CHIMNEYNOTE: Masonry chimney installations are not permitted.NOTE: All venting connections must be in compliance with the chimney manufacturers installationinstructions.This appliance was tested to CAN/ULC S610 and UL 127 Factory Built Fireplace Standards. This appliancehas met the test criteria for Zero Clearance Installation to Combustible Surfaces and Certified to burn firewoodonly.Any chimney 10” (254mm) or 12” (30.5cm) diameter listed to CAN/ULC S610 for Canada or UL127 for theUnited States or to the following standards; CAN/ULC-S604 and CAN/ULC-S629 for Canada or UL-103 or UL-103HT for the United States may be installed.Installation of all types of factory-built chimney systems is tobe in accordance with the chimney manufacturers installationinstructions. An appropriate chimney manufacturers anchor baseplate and anchor base plate gasket is required in order to initiatetheir system. Use the high temperature gasket, supplied, toseal between the anchor plate and the appliance top. Air cooledchimney systems are not recommended in colder climates.Chimney sections must be adequately secured one to the other toensure they do not separate. For complete installation instructions,refer to instructions provided with the manufactured chimneysystem.A chimney venting the appliance shall not vent any other appliance. The minimum overall chimney height fromthe top of the appliance is 15ft (4.6m). The maximum overall chimney height from the top of the appliance is34ft (10.4m).Factory-built chimney systems for use in dwellings constructed for three or more families must be enclosedabove the room in which the appliance is located. This enclosure must have a fire resistance rating equal to orgreater than that of the floor or roof assembly through which they pass.The chimney should not be built with an offset angle in excess of 45° in Canada and 30° in USA.Ensure that minimum clearances are maintained.Portions of the chimney that extend through accessible spaces must always be encased to avoid personalcontact with the chimney and thereby avoid damage to the chimney.The chimney must be supported at a maximum of 20ft (6.1m) intervals. Every 20 ft (6.1m) of chimney canweigh up to approximately 200lbs (90.7kg). When using a 10" chimney, center anchor plate to appliance flueoutlet.ANCHOR PLATEANCHOR PLATE GASKETAPPLIANCE TOPANCHOR PLATE FOR A FACTORYBUILT CHIMNEY