W415-1802 / D / 10.24.19EN14finishing3.0 finishingCombustible mantel clearance can vary according to the mantel depth. Use the graph to help evaluate the clear-ance needed. These same requirements apply to any combustibles protruding on either side of theappliance.3”12”5”4”MANTEL DEPTH0” (mm)+(,*+70$17(/6”15”16”17”3.1 minimum combustible mantel clearances12”(30.5cm)17”(43.2cm)16”(40.6cm)15”(38.1cm)6”(152.4mm)MANTEL5”(127mm)3” (76.2mm)4”(101.6mm)20 15/16 ”(53.1cm)6”(152mm)! WARNING• Risk of fire!• Never obstruct the front opening of the appliance.• The front of the appliance must be finished with any non-combustible materials such as brick, marble, granite,etc., provided that these materials do not go below the specified dimension, as illustrated.• Do not strike, slam, or scratch. Do not operate appliance with glass removed, cracked, or scratched.• Facing and/or finishing material must never overhang into the appliance opening.• The glass door assembly is a safety device designed to pivot forward when relieving excess pressure thatmight occur. Finishing or other materials must not be located in the opening surrounding the door as this willinterfere with the doors ability to relieve pressure.• If applicable, drywall dust will penetrate into the blower bearings, causing irreparable damage. Care mustbe taken to prevent drywall dust from coming into contact with the blower or its compartment. Any damageresulting from this condition is not covered by the warranty policy.! WARNING• Risk of fi re. Maintain all specifi ed air space clearances to combustibles. Failure to comply with these instructionsmay cause a fire or cause the appliance to overheat. Ensure all clearances (i.e. back, side, top, vent, mantel,front, etc.) are clearly maintained.• When using paint or lacquer to finish the mantel, the paint or lacquer must be heat resistant to preventdiscolouration.