17W415-0536 / D / 05.18.07BLOWERMOUNTINGPLATEREMOVE 4 SCREWSBLOWER REPLACEMENTThe Napoleon® PARK AVENUE™ comes equipped with aheat circulating blower. The blower is pre-wired and is con-trolled by the remote control supplied with the unit. For controldetails, see operation. Pg. 22.Drywall dust will penetrate into the blower bearings, caus-ing irreparable damage. Care must be taken to preventdrywall dust from coming into contact with the blower orits compartment. Any damage resulting from this condi-tion is not covered by the warranty policy.1. Turn off the power to the fireplace.2. Turn off the gas valve.3. Remove the glass door, logs, rear log supports, brickpanels, air deflector, burner assy, panel support, panel sup-port bracket.4. The blower mounting plate can now be removed. Removethe four screws that secure the plate to the firebox base.5. The blower is secured to the firebox. Disconnect the wireconnectors before attempting to remove the blower from thefirebox.6. Remove the two screws securing the blower and lift throughblower access opening.FIGURE 37REMOVE 2 SCREWSYour PARK AVENUE™ comes equipped with our “NightLight™”. The light has been pre-wired and is controlled fromthe remote control.If in the event the lamp or lens needs to be replaced, followthe instructions below.Unplug the wireharness/ transformer from thejunction box inside thefireplace.NIGHT LIGHT™ REPLACEMENTSCREWSLENSEFRAMEFIREBOX TOPFIGURE 40Remove the four screws that secure the lens frame.This frame retains the glass lens. The lamp can now beaccessed.Note: Do not handle the lamp (bulb) with bare fingers,protect with a clean dry cloth.The lamp will pull straight out of the socket. Replace withWolf Steel parts only, as lamp and lens are special “hightemperature” products.When re-installing, ensure integrity of gasket seal.THE FIREBOX MUST BE SEALED.Over tightening the screws could break the lens.“Light Leakage” from the upper area may be observed.The holes in the lamp housing are necessary forventilation and must not be covered.FIGURE 39FIGURE 41GASKETLENSEFRAMECOLOURED SIDE UPNote: When re-installing the replace-ment blower, it will be necessary toreplace the gasket (W290-0104) onthe blower mounting plate.FIGURE 38