25W415-0748 / 12.12.085.0 FRAMING! WARNINGIn order to avoid the possibility of exposed insulation or vapour barrier coming in contact with thefireplace body, it is recommended that the walls of the fireplace enclosure be “finished” (ie: drywall /sheetrock), as you would finish any other outside wall of a home. This will ensure that clearance tocombustibles is maintained within the cavity.Do not notch the framing around the appliance stand-offs. Failure to maintain air space clearancemay cause over heating and fire. Prevent contact with sagging or loose insulation or framing andother combustible materials. Block opening into the chase to prevent entry of blown-in insulation.Make sure insulation and other materials are secured.It is best to frame your fireplace after it is positioned and the ventsystem is installed. Use 2x4’s and frame to local building codes.For convenience, the standoffs have been shipped flat. Beforeframing, ensure the standoffs are opened and screwed in place.It is not necessary to install a hearth extension, but the fireplaceshould be raised to be flush with either the hearth or the finishedfloor.W385-0395WARNINGTHE STANDOFFS HAVEBEEN SHIPPED FLAT.BEFORE FRAMINGENSURE THE STANDOFFSARE BENT AND SCREWEDINTO PLACE.ATTENTION ATENCIÓNLAS TRABAS PERMANECENPLANAS DURANTE EL ENVÍO.ANTES DE LA INSTALACIÓN,VERIFIQUE QUE LAS TRABASSE PLIEGUEN Y ATORNILLENCORRECTAMENTE.LES ESPACEURS SONTEMBALLÉS À PLAT. AVANT DECONSTRUIRE L'OSSATURE,ASSUREZ-VOUS QUE LESESPACEURS SONT PLIÉSET FIXÉS EN PLACE ÀL'AIDE DE VIS.Maintain these minimum clearances to combustibles from fireplace and vent surfacesNon-combustible fi replace fi nishing:- 4” from the sides of the fireplace opening- 22 3/8” to the top of the fireplace openingCombustible fi replace fi nishing:- 0” to rear and sides- 2” all around the vent pipe*- 22 1/2” recessed depth- 72” from bottom of unit to enclosure top and from the bottom of unit to ceiling*HORIZONTAL VENT SECTIONS: A minimum clearance of 2” all around the vent pipe on all horizontal runs tocombustibles is required. Use firestop spacer W010-1799 (supplied).*VERTICAL VENT SECTIONS: A minimum of 1” all around the vent pipe on all vertical runs to combustibles isrequired except for clearances in fireplace enclosures. Use firestop spacer W500-0096 (not supplied).