XR12 Operations and Maintenance Manual Using the event logIssue 3.1 2013-03-14 Page 3-3Figure 3.2: View Event Page 1View Event page 2. View Event Page 2 provides information about forward power,reflected power, total dc current, and VSWR.Figure 3.3: View Event Page 2If the VSWR cannot be calculated (for example, when forward power is 0 W), N/Aappears.View Event page 3. View Event Page 3 provides information about all dc voltages in thetransmitter. Available measurements are B+ voltage, PA voltage, RF drive P/S voltage (62 VP/S), fan P/S voltage (48 V P/S), +24 V, +15 V, -15 V and +5 V power supplies.10:18 0.00kW M-1 PM:AB Man Ex:A Man001 24Oct06 10:48:43 LVPS FaultRF Power: Off Fwd Power:0.00kWControl: Local Shutback:YesExciter: A Man Cutback: 0PM: AB Man Preset: M-1Use Up/Dn Keys to view event data. 1/5Next Event Back10:18 0.00kW M-1 PM:AB Man Ex:A Man001 24Oct06 10:48:43 LVPS FaultRF Power: Off Fwd Power:0.00kWControl: Local Shutback:YesExciter: A Man Cutback: 0PM: AB Man Preset: M-1Use Up/Dn Keys to view event data. 1/5Next Event BackScroll BarPage numberindicator10:18 0.00kW M-1 PM:AB Man Ex:A Man001 24Oct06 10:48:43 LVPS FaultForward Power: 0.00kWReflec. Power: 0WTotal DC Curr: 0.0AVSWR: N/AUse Up/Dn Keys to view event data. 2/5Next Event Back10:18 0.00kW M-1 PM:AB Man Ex:A Man001 24Oct06 10:48:43 LVPS FaultForward Power: 0.00kWReflec. Power: 0WTotal DC Curr: 0.0AVSWR: N/AUse Up/Dn Keys to view event data. 2/5Next Event Back