11© by N&W GLOBAL VENDING SpA 07 06 275- 00Chapter 2INSTALLATIONInstallation and the following maintenance operationsshould be carried out with the machine switched on andtherefore by qualified personnel only, who are trained inthe correct use of the machine and informed about thespecific risks of such situation.The machine is not suitable for outdoor installation, it mustbe installed in a dry room where the temperature remainsbetween 2° C and 32° C.The machine cannot be installed where water jets are usedfor cleaning.At installation the hydraulic circuits and the parts incontact with foodstuff should be fully sanitised toremove any bacteria which might have formed duringstorage.POWER SUPPLY SWITCHESMainA main switch is fitted outside the machine, disconnectingthe power from the machine without having to open thedoor.The terminal strip supporting the line cable, the fusesand the noise suppressor stay energised in any case.DoorWhen opening the door a special microswitch disconnectsthe power from the machine electrical system.To energize the system with the open door, simply insertthe special yellow key into the slot (see Fig. 14).Top panelAlso when opening the machine top panel, a switchdisconnects the power, allowing loading operations in asafe condition.The switch on key MUST NOT be left inside the ma-chine, it must be kept by the qualified personneltrained in the use of the machine.With the door open, there is no access to energisedparts. Inside the machine, the only parts that stayenergised are those protected by covers and carryinga plate with the warning “disconnect the power beforeremoving the protective cover”.Before removing such covers disconnect the powersupply cable from the grid.The door can be closed only after removing the key fromthe door switch.UNPACKING THE VENDING MACHINEAfter removing the packing, ensure that the machine isintact.If in doubt do not use the machine.No packing elements (i.e. plastic bags, polystyrenefoam, nails, etc.) should be left within the reach ofchildren, as they are potentially dangerous.Packing materials must be disposed of in authorisedcontainers and the recyclable ones must be recovered byqualified companies.Important notice!!The machine should be positioned with a maximum incli-nation of 2°.A side module (optional) can be added to the machine toenhance its performance.With some modules it may be necessary to fit a gasket toseal the space between machine and support counter.The gasket is supplied separately from the module.For installation, lay the machine on its back and fit thegasket (see figure 15) following the installation instructionssupplied with the kit.Fig. 141 - Door switch2 - Network fuses3 - External switch4 - Top panel switchFig. 151 - Side module (optional)2 - Gasket