68 - FORM NO. 56043093 / Captor™ 4300, 4800, 5400HYDRUALIC SYSTEMPump Circuit DISPL GPMRPM(in) RPM (out) PSI Relief PSIPump Circuit (1) Engine @ 2400rpms No Load (XT1) .58 cu.in. 6 2400 *675 2700Main Broom @ sweep postion (Std Broom 2.5"pattern) 3.6cu. in. 6 370 - 390 1400 - 1800 2700Vacuum Fan .16 cu.in. 6 6800-7100 1575 2700Hydrostat Charge 150Main Broom over pressure indicator switch (light) 2400Pump Circuit (2) Engine @ 2400rpms No Load (XT2) .58cu.in. 6 2400 *1200 2400Pump Circuit (2A) 1.75Steering System 4.5cu.in. 1.75 **1850Dump Door (open/close time 2 - 3 sec.) 1.75 **1850Hopper Lift (Extend time 15.4 sec.) Empty 1.75 **1850Pump Circuit (2B) Engine @ 2400rpms No Load 6 *1200 2400Engine Fan .32 cu. in. 4.3 2900-3000 1200 2400Dust Control .16 cu. in 4.3 4950 1550 2400Side Brooms 8.9 cu.in. 4.3 106 1250 2400Pump Circuit (3) Engine @ 2400rpms No Load (XT3) .50 cu.in 5.2 2400 *300 2400Scrub (1) Std. 180 grit brush on sealed concrete 4.5 cu.in 5.2 270 650 2400Scrub (2) Std. 180 grit brush on sealed concrete 4.5 cu.in 5.2 265 1000 2400Scrub (3) Std. 180 grit brush on sealed concrete 4.5 cu.in 5.2 255 1350 2400Scrub (1) Black pad on sealed concrete 4.5 cu.in 5.2 270 800 2400Scrub (2) Black pad on sealed concrete 4.5 cu.in 5.2 265 1200 2400Scrub (3) Black pad on sealed concrete 4.5 cu.in 5.2 255 1650 2400Scrub Deck Cylinder (Pressure Setting 1) piston end 0 0Scrub Deck Cylinder (Pressure Setting 2) piston end ***160Scrub Deck Cylinder (Pressure Setting 3) piston end ***160Scrub up 800 800Squeegee Up/Down 800 800Propulsion Pump CircuitHydrostatic Pump 1.44 cu. in. 14.9 2400 2500Wheel Motor @ 6mph (level surface) 19.8 cu. in. 10.8 Fwd 126 1000Rev. 73* The bypass pressure is the pressure reading with no motor or cylinder operating.** Total steering relief pressure at pump. (Sum of 1450 plus line pressure = 1850)*** Adjustable pressure flow valve. Factory setting 160psi.GENERAL HYDRAULIC SPECIFICATIONS TABLE