![Nilfisk-Advance Convertamatic 24 Instructions For Use Manual Manual pdf 17 page image](https://manuals-archive2.s3.amazonaws.com/3963416/c89bb58e6626d8d83d8655131912833d17f.jpg)
ENGLISH / A-17FORM NO. - 56041596 - Convertamatic ™ 24, 26, 28, 32 / BA 625, 725, 825 - A-17CHARGING WET BATTERIESCharge the batteries each time the machine is used or when the Battery Indicator (D) is reading less than full.WARNING!Do not fill the batteries before charging.Charge batteries in a well-ventilated area.Do not smoke while servicing the batteries.When Servicing Batteries...* Remove all jewelry* Do not smoke* Wear safety glasses, rubber gloves and a rubber apron* Work in a well-ventilated area* Do not allow tools to touch more than one battery terminal at a time* ALWAYS disconnect the negative (ground) cable first when replacing batteries to prevent sparks.* ALWAYS connect the negative cable last when installing batteries.If your machine shipped with an onboard battery charger do the following:Turn the Key Switch (A) OFF. Unwind the electrical cord from the side of the onboard charger and plug it into a properly grounded outlet. Refer to the OEM product manual for moredetailed operating instructions.If your machine shipped without an onboard battery charger do the following:Disconnect the batteries from the machine and push the connector from the charger into the Battery Pack Connector (25). Follow the instructions on the battery charger. SERVICENOTE: Make sure you plug the battery charger into the connector with the handle attached to it.CAUTION!To avoid damage to floor surfaces, wipe water and acid from the top of the batteries after charging.CHECKING THE BATTERY WATER LEVELCheck the water level of the batteries at least once a week.After charging the batteries, remove the vent caps and check the water level in each battery cell. Use distilled or demineralized water in a batteryfilling dispenser (available at most auto parts stores) to fill each cell to the level indicator (or to 10 mm over the top of the separators). DO NOT over-fill the batteries!CAUTION!Acid can spill onto the floor if the batteries are overfilled.Tighten the vent caps. Wash the tops of the batteries with a solution of baking soda and water (2 tablespoons of baking soda to 1 liter of water).CHARGING GEL (VRLA) BATTERIESCharge the batteries each time the machine is used or when the Battery Indicator (D) is reading less than full.WARNING!Charge batteries in a well-ventilated area.Do not smoke while servicing the batteries.When Servicing Batteries...* Remove all jewelry* Do not smoke* Wear safety glasses, rubber gloves and a rubber apron* Work in a well-ventilated area* Do not allow tools to touch more than one battery terminal at a time* ALWAYS disconnect the negative (ground) cable first when replacing batteries to prevent sparks.* ALWAYS connect the negative cable last when installing batteries.CAUTION!Your voltage regulated lead acid (VRLA) battery will deliver superior performance and life ONLY IF IT RECHARGED PROPERLY!Under or overcharging will shorten battery life and limit performance. Be sure to FOLLOW PROPER CHARGING INSTRUCTIONS!DO NOT ATTEMPT TO OPEN THIS BATTERY! If a VRLA battery is opened, it loses its pressure and the plates become oxygencontaminated. THE WARRANTY WILL BE VOIDED IF THE BATTERY IS OPENED.If your machine shipped with an onboard battery charger do the following:Turn the Key Switch (A) OFF. Unwind the electrical cord from the side of the onboard charger and plug it into a properly grounded outlet. Refer to the OEM product manual for moredetailed operating instructions.If your machine shipped without an onboard battery charger do the following:Disconnect the batteries from the machine and push the connector from the charger into the Battery Pack Connector (25). Follow the instructions on the battery charger. SERVICENOTE: Make sure you plug the battery charger into the connector with the handle attached to it.IMPORTANT: Make sure you have an appropriate charger for use on Gel cell batteries. Use only “voltage-regulated” or “voltage-limited”chargers. Standard constant current or taper current chargers MUST NOT be used. A temperature-sensing charger is recommended, asmanual adjustments are never accurate and will damage any VRLA battery.revised 5/05